                                                          Operation
 
 
MODEL GL-C Installation & Operation MANUAL Rev. 1.02–6/27/2007   
                                    
Page 
6
 
 
Adjustments To Rinse Agent Pump: 
• 
Follow same procedures as detergent for priming chemical. 
• 
Cycle glasses through machine and verify glasses are sheeting properly. Increase rinse aid as 
necessary by turning up or down circuit set screw. 
• 
Basic circuit board setting is 9:00.  
Note: To meet standards set by NSF, chlorine at 50ppm must be used in the final rinse. 
 
4.3. Cleaning 
Instructions 
4.3.1. Highly Recommended Daily Cleaning Instructions 
Remove optional GL-C drain tray & waste collector from the front of your glasswasher and clean 
thoroughly. 
Turn power switch off behind front service door.  
Remove all trays, screens and curtains. Wash, rinse them thoroughly and allow to dry. 
Move shut-off rod to side and remove conveyor hub and wheel from machine.  
Remove and clean wash and rinse arms. Wash tube brush and jet reamer supplied for cleaning of 
arms. 
         CAUTION:  Do not twist spray arms, pull straight out or they will break 
Install wash and rinse arms (Wash and rinse arms are different .The receiver arm sockets are molded 
differently to prevent placing arms in wrong location). 
Use reverse procedures for placing conveyor wheel and hub back into position. 
Note: conveyor motor can be pulled to the side as your placing wheel into position. Open 
front access door and pull conveyor motor toward you as seat the conveyor wheel into 
position. 
Place conveyor hub in center of conveyor, align shut-off rod to normal position. Install left and right 
trays, making sure shut-off rod is positioned between guide brackets. Install curtains into their 
holders. 
Upper and lower wash tank screens should be removed and cleaned thoroughly. 
Pull the drain tube from the soap tank and clean the tank.  
Insert overflow drain tube and wash tank screens back to appropriate placement. 
Reattach optional GL-C waste collection assembly. 
Check product levels and close front service door. 
 
4.3.2. Weekly Cleaning Instructions 
Remove upper and lower wash and rinse arms from their spray bases, remove end plugs, and clean 
spray tubes with Cleaning Drill p/n 00899.01, Cleaning Brush p/n 00899.02 provided.