Exporting or Exchanging Cartridges in a Cleaning Partition
December 2008
Spectra T950 Library
69
3. Select the Export/Exchange or Export/Exchange Expired.
The transporter retrieves a magazine from the cleaning partition and 
places it in the TAP. The TAP door opens and a Feedback Required 
screen displays. If you selected Export/Exchange Expired, the feedback 
screen tells you which cartridge to remove from the magazine.
4. Remove the magazine from the TAP.
ƒ If you are removing the entire magazine of cleaning cartridges from 
the cleaning partition and will not be replacing it, skip to 
ƒ If you are replacing an expended cleaning cartridge with a new one, 
exchange the cleaning cartridge in the slot indicated in the feedback 
screen for a new one of the same type.
5. Return the magazine to the open TAP, making sure that it is correctly 
oriented.
6. Select either Continue or Stop Exporting.
ƒ Select Continue if you want to export additional magazines. The 
library returns the magazine to its original location. 
Note:
If you exchanged an expended cleaning cartridge for a new one, 
select Ok in response to a message stating that the slot containing 
the exchanged cartridge should be empty. 
The export process continues automatically as long as there are 
magazines left in the cleaning partition. Simply continue to remove 
magazines from the TAP and select Continue for each one.
When the all magazines in the cleaning partition have been 
exported or exchanged, the process stops automatically and the user 
interface redisplays the Import/Export TeraPack Cases screen.
ƒ Select Stop Exporting after you remove the last magazine if you do 
not want to export all of the cleaning magazines in the cleaning 
partition.