Installation
Dimming Terminal Connection
1. T-BAR
• Make sure to turn off the main power switch of the installation space before connection.
• Connect so that the colors of the 3 power cables match. (LIVE: BROWN, NEUTRAL: BLUE, P.E.: GREEN/YELLOW)
1
Drill and prepare the
ceiling so the hole is
smaller than the 
product.
2
Connect the 3 product
cables to the interior
wiring of the building.
For wire connectors,
use standardized 
products.
3
Rotate the connected
product by 20 degrees.
Then insert it into the 
T-Bar insertion space.
• Make sure that all 4
sides of the product
match the T-Bar.
4
Place the horizontal
product into the T-Bar.
5
Ensure the inserted
product is horizontal.
NEUTRAL
LIVE
P.E.
NEUTRAL
LIVE
P.E.
NEUTRAL
LIVE
P.E.
NEUTRAL
LIVE
P.E.
Interior wiring 
of the building
Wire connectors 
Product’s 
power cables
NEUTRA
NEUTRALL
LIV
LIVEE
P.E
P.E..
NEUTRAL
LIVE
P.E.
2. M-BAR
• Make sure to turn off the main power switch of the installation space before connection.
• Connect so that the colors of the 3 power cables match. (LIVE: BROWN, NEUTRAL: BLUE, P.E.: GREEN/YELLOW)
• Use woodscrews provided by LG Electronics.
(In case of a model of 620 M-Bar, Use silver colored screws if the ceiling tiles are thicker than 9.0t. If not, use black colored screws.)
1
Drill and prepare the
ceiling so that the hole
is smaller than the 
product.
2
Connect the 3 product
cables to the interior
wiring of the building.
For wire connectors,
use standardized 
products.
3
Check the installation
location.
4
Fix the product by using
woodscrews.
• Check to see that the
product is fixed into
place.
5
Perform a lighting test
to see if the product is
working properly.
• After the installation is
complete, remove the
protective sheet.
6
Once installation is complete, turn on the
power switch to check it is operating properly. 
• After the installation is complete, remove the
protective sheet.
※ During the use of connector socket, if the power line
is forced in, it may not be lighted due to defect 
contact.
※ When this luminaire is connected to branch circuit, 
installation engineer must use the connector that meets
the glow-wire test of 650°C (in case of France, 850°C)
or higher.
-Connector Socket-
-Dimming Connector-
(O)
(X)
※ When each cable is inserted into the 
dimming connector socket, the wire which
removes the covering must not come into
contact with the case.
To dim the lamps, a compatible dimmer should be used.
The use of incompatible dimmers will result in damage to the products.
Before installing dimmers, verify the compatible dimmer list with your local LGE sales representative.
※ Wire dimming function is included. (0-10V)
※ Please use wire with designated thickness. (24-20AWG)
※ Be careful of the polarity for correct dimming control.
※ Maximum number of products to be connected to 
1 dimming controller: 20 (Compatible dimmer: 
ArteorTM Fluo Dimmer (Legrand Electric Ltd.), 
AU-DSPLED (Aurora Ltd.))
※ The function of dimming control may not be served depending on the product.
1
2
Pin No.
Output Name
1
0~10V
2
GND
- 1 -
LED FLAT LIGHT
Installation Manual
• Please read the 
「Safety Precautions」prior to install for your safety.
• This manual is intended to prevent product damage and protect the user’s safety.
• Violation of warnings may lead to serious injury or death.
Safety Precautions
WARNING
Turn power off before 
contact of the product.
• Risk of electric shock.
Install a circuit breaker.
• Risk of fire and electric shock.
Use with proper rated 
voltage. (less than ±10%)
• Risk of fire and product damage.
Perform grounding work. 
•  Risk of electric shock.
Electric work must be 
performed by a certified 
technician according to the
installation manual.
• Inadequate power capacity and
faulty electric work may lead to
fire or electric shock.
Do not randomly connect the
power polarities.
• Risk of product damage and 
accidents.
Do not install in areas that
have risks of flooding.
• Risk of electric shock and fire.
Do not use the product if 
impurities are present in the
product or if the product is
submerged.
• Risk of accidents such as electric
shock and product damage.
Do not store in a humid area. 
• Risk of product malfunctioning.
If the lamp turns off by itself, do
not disassemble the product.
Contact your local LGE sales
representative for repair.
• Risk of electric shock and 
product  malfunctioning.
Do not stare directly at the
lamp when turned on.
• Strong light may cause visual 
impairment.
Do not expose the product to
water when cleaning it.
• Risk of fire and electric shock.
Do not use if the product has
been dropped or exposed to
shock. 
• Risk of product malfunctioning.
Must have at least two or
more people working during
installation.
• Risk of product dropping and
causing injury to the user.
Product is heavy. Use a 
trolley when transporting the
product.
• Dropping the product may cause
product damage and 
malfunction.
Do not install where it may
be exposed to direct 
sunlight, humidity, or dust.
Do not clean the product with
inflammable substances
such as alcohol, benzene,
and acetone that may alter
the surface.
Do not install near potential
sources of fire or 
inflammable objects, such as
paper or cloth.
• Risk of product malfunctioning
and   accidents.
Do not disassemble or arbitrarily
remodel the product. Do not use for
underwater lighting purposes. 
(Underwater landscape, 
searchlight, fishing, events, etc.)
• Risk of fire and electric shocks.
Must fix the product properly
on the ceiling. 
• Risk of product dropping and
causing injury to the user.
• Violation of precautions may lead to light injury or product damage.
CAUTION
MFL67703801