EXTERNAL CONTROL DEVICE SETUP
ENG
ENGLISH
Command reference list
Communication Parameters
 
y
Baud rate: 9600 bps (UART)
 
y
Data length: 8 bits
 
y
Parity : None
 
y
Stop bit: 1 bit
 
y
Communication code: ASCII code
 
y
Use a crossed (reverse) cable.
 
y
* Note : During USB operations such as DivX or EMF, all commands except Power(ka) and Key(mc) are 
not executed and treated as NG.
(Depending on model)
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
01. Power
k
a
00 to 01
13. Treble
k
r
00 to 64
02. Aspect Ratio k
c
14. Bass
k
s
00 to 64
03. Screen Mute k
d
15. Balance
k
t
00 to 64
04. Volume Mute k
e
00 to 01
16. Colour  
Temperature
x
u
00 to 64
05. Volume 
Control
k
f
00 to 64
17. Energy 
Saving
j
q
00 to 05
06. Contrast
k
g
00 to 64
18. Auto Configu-
ration
j
u
01
07. Brightness
k
h
00 to 64
19. Tune 
Command
m
a
08. Colour
k
i
00 to 64
20. Programme 
Add/Skip
m
b
00 to 01
09. Tint
k
j
00 to 64
21. Key
m
c
Key Code
10. Sharpness
k
k
00 to 64
22. Control Back 
Light
m
g
00 to 64
11. OSD Select
k
l
00 to 01
23. Input select 
(Main Picture 
Input)
x
b
12. Remote 
Control
Lock Mode
k
m
00 to 01