LG 50PV350 Owner's Manual

Page of 140
115
ENG
ENGLISH
EXTERNAL CONTROL DEVICE SETUP
*  Real data mapping 
00 : Step 0
A : Step 10 (Set ID 10)
F : Step 15 (Set ID 15)
10 : Step 16 (Set ID 16)
64 : Step 100
6E : Step 110
73 : Step 115
74 : Step 116
CF : Step 199
FE : Step 254
FF : Step 255
24. Input select (Command: x b)
  
(Main Picture Input)
 
► To select input source for main picture.
Data  Structure
MSB 
LSB
Transmission [x][b][  ][Set ID][  ][Data][Cr]
External Input
Input Number
0
0
0
0
0
0
0
0
Ack [b][  ][Set ID][  ][OK/NG][Data][x]
External Input
Data
0
0
0
0
DTV
0
0
0
1
Analogue
0
0
1
0
AV
0
1
0
0
Component
0
1
1
0
RGB
0
1
1
1
HDMI
1
0
0
0
1
0
0
1
1
0
1
0
Input Number
Data
0
0
0
0
Input1
0
0
0
1
Input2
0
0
1
0
Input3
0
0
1
1
Input4
25. 3D(Command: x t) (only 3D models)
 
► To change 3D mode for TV.
Data Structure
Data01     00 : 3D On
   
   01 : 3D Off
   
   02 : 3D to 2D
   
   03 : 2D to 3D
Data02      00 : Top and Bottom
   
   01 : Side by Side
   
   02 : Check Board
   
   03 : Frame Sequential
Data03       00 : Right to Left
   
   01 : Left to Right
Data04      3D Effect(3D Depth) : Min : 00 ~ Max : 14
   
   (*transmit by Hexadecimal code)
*If data1 is 00(3D On), data4 has no meaning.
*If data1 is 01(3D off) or 02(3D to 2D), data2, data3 and
data4 have no meaning.
*If data1 is 03(2D to 3D), data2 and data3 have no
meaning.
Transmission [x][t][ ][Set ID][ ][Data01][ ][Data02]
[ ][Data03][ ][Data04][Cr]
Ack [t][ ][OK][Data01][Data02][Data03][Data04][x]
[t][ ][NG][Data01][x]
26 . Extended 3D(Command: x v) (only 3D models)
 
► To change 3D option for TV.
Data01 : 3D option
   
  00 : 3D Picture Correction
   
  01 : 3D Depth(Only 2D to 3D)
   
  02 : 3D Viewpoint
   
  03 : 3D Picture Size(Only Plasma TV)
   
  04 : 3D Picture Balance (Only Plasma TV)
   
  05 : 3D Optimization(Only Active type (LCD TV))
Data02 It has own range for each 3D option determined
   
by Data01.
1) When Data 01 is 00
   
  00 : Right to Left
   
  01 : Left to Right
2) When Data 01 is 01, 02
Data       Min: 0 ~ Max: 14
3) When Data 01 is 03
   
  00 : Just Scan
   
  01 : 16:9
4) When Data 01 is 04
   
  00 : Off
   
  01 : On
5) When Data 01 is 05
Data      Min: 0 ~ Max: 02
   
 * Refer to ‘Real data mapping’.
Transmission [x][v][ ][Set ID][ ][Data01][ ]
[Data02][Cr]
Ack [v][ ][OK][Data01][Data02][x][v][ ][NG]
[Data01][x]
Data 1
Data 2
Data 3
Data 4
00
O
O
X
01
X
X
X
02
X
X
X
03
X
X
O
X : don’t care