LG DLGX3876V User Manual

Page of 100
18
Electrical Requirements for Gas Models Only
•  
Do not, under any circumstances, cut or 
remove the third (ground) prong from the power 
cord. Failure to follow this warning can result in 
fire, explosion, or death.
•  
For personal safety, this dryer must be properly 
grounded. Failure to follow this warning can result 
in fire, explosion, or death.
•  
The power cord of this dryer is equipped with 
a 3-prong (grounding) plug which mates with 
a standard 3-prong (grounding) wall outlet 
to minimize the possibility of electric shock 
hazard from this appliance. Failure to follow this 
warning can result in fire, explosion, or death.
•  
This dryer must be plugged into a  
60 Hz, 120 VAC. grounded outlet protected by 
a 15-ampere fuse or circuit breaker. Failure to 
follow this warning can result in fire, explosion,  
or death.
Where a standard 2-prong wall outlet is  
encountered, it is your personal responsibility 
and obligation to have it replaced with a 
properly grounded 3-prong wall outlet. Failure  
to follow this warning can result in fire, explosion, 
or death.
CONNECTING GAS DRYERS
Gas supply requirements:  
As shipped from the factory, this dryer is 
configured for use with natural gas. It can be 
converted for use with LP (Liquefied Propane) 
gas. Gas pressure must not exceed 13 inches 
of water column.
A qualified service or gas company technician 
must connect the dryer to the gas service. 
Failure to do so can result in fire, explosion,  
or death.
Isolate the dryer from the gas supply system 
by closing its individual manual shutoff valve 
during any pressure testing of the gas supply. 
Failure to do so can result in fire, explosion,  
or death.
Supplylinerequirements: 
Your laundry room must have a rigid gas 
supplylinetoyourdryer.IntheUnitedStates,
anindividualmanualshutoffvalveMUSTbe
installed within at least 6 ft. (1.8 m) of the dryer, 
in accordance with the National Fuel Gas Code 
ANSIZ223.1orCanadiangasinstallationcode
CSAB149.1.A
1
- inch NPT pipe plug must 
be installed. Failure to do so can result in fire, 
explosion, or death
If using a rigid pipe, the rigid pipe should be  
½-inchIPS.Ifacceptableunderlocalcodes
and ordinances and when acceptable to your 
gas supplier, 
3
- inch approved tubing may be 
used where lengths are less than 20 ft.  
(6.1 m). Larger tubing should be used for 
lengths in excess of 20 ft. (6.1 m). Failure to do 
so can result in fire, explosion, or death.
Connect the dryer to the type of gas shown on 
the nameplate. Failure to do so can result in fire, 
explosion, or death.
To prevent contamination of the gas valve, 
purge the gas supply of air and sediment 
before connecting the gas supply to the dryer. 
Before tightening the connection between the 
gas supply and the dryer, purge remaining air 
until the odor of gas is detected. Failure to do 
so can result in fire, explosion, or death.
DO NOT use an open flame to inspect for gas 
leaks. Use a noncorrosive leak-detection fluid. 
Failure to do so can result in fire, explosion, or 
death. 
UseonlyanewAGA-orCSA-certifiedgas
supply line with flexible stainless steel 
connectors. Failure to do so can result in fire, 
explosion, or death.
Securelytightenallgasconnections. Failure  
to do so can result in fire, explosion, or death.
Use Teflon
®
 tape or a pipe-joint compound that 
is insoluble in Liquefied Petroleum (LP) gas on 
all pipe threads. Failure to do so can result in fire, 
explosion, or death.
DO NOT attempt any disassembly of the dryer; 
any disassembly requires the attention and 
tools of an authorized and qualified service 
person or company. Failure to do so can result  
in fire, explosion, or death.
w
WARNING: 
To reduce the risk of fire, electric shock, or personal injury when using this  
appliance, follow basic precautions, including the following:
w
WARNING: 
To reduce the risk of fire, electric shock, or personal injury when using this  
appliance, follow basic precautions, including the following: