LG DLEX2501R User Guide

Page of 134
21
Remove the terminal block access cover  
on the upper back of the dryer. Install a  
UL-listed strain relief into the power cord 
through-hole; then thread a UL-listed, 
30A, 
240V, 3-wire, #10 AWG-minimum copper 
conductor power cord through the strain 
relief.
1
Attach the two hot leads of the power cord 
to the outer terminal block screws. Attach 
the neutral wire to the center terminal block 
screw. Connect the external ground (if 
required by local codes) to the green ground 
screw. TIGhTEN ALL SCREWS SECURELY. 
Reinstall the terminal block access cover.
2
Three-Wire Connection for Electric Dryers: Power Cord 
•  A 3-wire connection is NOT permitted on new
construction after January 1, 1996. 
•  A UL-listed strain relief is required.
•  Use  a
30-amp,  240V,  UL-listed  power  cord  
with  #10  AWG-minimum  copper  conductor  
and  closed  loop  or  forked  terminals  with 
upturned ends.
CONNECTING ELECTRIC DRYERS 
(cont.)
Ground Screw
UL-Listed 
Strain Relief
Terminal 
Block
Ground Wire
 hot 
 (Black)
hot 
(Red)
Neutral 
(White)
w
WARNING: 
•Connect the power cord to the terminal block. Each colored wire should be connected  
to same color screw. Wire color indicated on manual is connected to the same color 
screw in block. Failure to follow these instructions may result in a short or overload.
•Grounding through the neutral conductor is prohibited for: (1) new branch-circuit  
installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local  
codes prohibit grounding through the neutral conductor.
UL-Listed  
3-Wire  
Power Cord
USA ONLY
3828EL3003V_en.indd   21
2009.7.14   3:18:12 PM