Omnitron FlexPoint Gx 4372-1 Leaflet
Product codes
4372-1
800-675-8410 • 949-250-6510 • www.omnitron-systems.com • info@omnitron-systems.com • 140 Technology Dr. Irvine, CA 92618
© 2010 Omnitron Systems Technology, Inc. All rights reserved. FlexPoint is a Trademark of Omnitron Systems Technology, Inc.
Trademarks are owned by their respective companies. Specifications are subject to change without notice.
091-04370-004E 9/ 10
In this enterprise campus application example, FlexPoint Gx
media converters are installed in a 14-Module Redundant
Power chassis for high-density fiber distribution from UTP
switch equipment at the Network Core. A UTP workgroup
switch (A) is connected via fiber with a standalone FlexPoint
Gx media converter. Another FlexPoint Gx converts the fiber
to UTP in a fiber-to-desktop application (B). An Ethernet switch
(C) is connected directly via fiber to the FlexPoint module at
the Network Core. In all cases, multimode or single-mode
fiber can be used, and fiber links can be extended up to 80km
using single-mode fiber.
sPeCIFICatIONs
aPPlICatION examPle
OrderINg INFOrmatION
Model Type
Gx
Protocols
IEEE 802.3ab, 1000BASE-T, 1000BASE-X
UTP Cable
RJ45, Category 5 and higher
Fiber Cables
Multimode: 50/125, 62.5/125, 100/140µm
Single-mode: 9/125µm
UTP Connectors
RJ-45
Fiber Connectors SC, MT-RJ, LC
DIP-Switches
DIP-Switches
Auto-Neg, FDX/HDX, Pause En/Dis, Link Prop.
LED Displays
Power, Fiber Link/Activity, UTP Link/Activity, Full/Half-Duplex
Dimensions
W: 3.0" x D: 4.0" x H: 1.0"
Weight
6 oz. (without power adapter)
Compliance
UL, CE, FCC Class A
Power
Requirements
Nominal Voltage:
Voltage Range:
Power Nominal:
Maximum Power:
Barrel Connector
9VDC
6.0 to 15.0VDC
0.4A @ 9VDC
1A @ 9VDC
Molex Connector
5VDC
4.75 to 5.25VDC
0.6A @ 5VDC
0.75A @ 5VDC
Temperature
0 to 50o C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (Hours)
Module without Power Adapter: 990,000
Module with Power Adapter
-1: 250,000
Module with Power Adapter
-2: 100,000
Fiber Type
Distance
Connector Type
Tx / Rx
Wavelength
[nm]
Min. Tx
Power
[dBm]
Max. Tx
Power
[dBm]
Min. Rx
Sense
[dBm
Max. Rx
Power
[dBm]
Min.
Attenuation
(dB)
Optical
Power
Budget
ST
SC
MT-RJ
LC
MM
220 / 550m ¹
4376-x
4370-x
4670-x
4672-x
850
-10
-4
-17
-3
-
7
SM
12km
4377-x
4371-x
4671-x
4673-x
1310
-9.5
-3
-19.5
-3
-
10
SM
34km
-
4372-x
-
4674-x
1310
-5
0
-23
-3
3
18
SM
80km
-
4373-x
-
4675-x
1550
-5
0
-23
-3
3
18
SM
110km
-
4374-x
-
4676-x
1550
0
5
-24
-3
8
24
SM
140km
-
4375-x
-
4677-x
1550
2
5
-28
-8
13
30
Power Adapter Kits (-x): -0 = No power adapter included -1 = 110-120 VAC/60 Hz (US plug), -2 = 100-240 VAC/50-60 Hz (IEC plug, no power cord).
Contact Omnitron for other fiber options and operational temperature ranges.
¹ 62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm multimode fiber up to 550m. Refer to the fiber cable manufacturer for