KitchenAid 30'' Slow Cook Warming Drawer Dimensional Illustrations

Page of 2
24" (61 CM), 27" (68.6 CM), AND 30" (76.2 CM)
INDOOR/OUTDOOR ELECTRIC WARMING DRAWER
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
KOWT100E
KOWT104E
KOWT107E
IMPORTANT: Observe all governing codes and ordinances.
•  Cutout dimensions that are shown must be used. Given dimensions 
provide minimum clearance with warming drawer.
•  Recessed installation area must provide complete enclosure around 
the recessed portion of the warming drawer.
•  Grounded electrical supply is required. See “Electrical Requirements” 
section.
•  Electrical supply outlet should be located in the rear wall on the upper 
right-hand side of the cutout or in an adjacent cabinet. The outlet 
must be recessed. If the electrical outlet is located in an adjacent 
cabinet, a 1³⁄
8
" (3.5 cm) minimum diameter hole should have been 
drilled in the back of the cutout or support surface to pass the power 
supply cord through to the outlet.
•  Warming drawer support surface must be solid, level and flush with 
bottom of cabinet cutout.
•  Warming drawers with oiled bronze, black glass, and white glass 
panels are approved for indoor use only.
For best performance results make sure the warming drawer is leveled 
before completing installation. There is no way to level the warming 
drawer after it has been installed. If the installation is not level, the door 
may slide open or not seal tightly, allowing heat to escape.
D
C
A
E
B
WARMING 
DRAWER 
SIZE
OVEN 
DEPTH 
(A)
RECESSED 
WIDTH 
(B)
RECESSED 
HEIGHT 
(C)
OVERALL 
WIDTH 
(D)
DRAWER 
FRONT 
HEIGHT (E)
24" 
(61 cm)
23¹⁄
8
(58.7 cm)
22¹⁄
4
(56.5 cm)
9" (22.9 cm)
23³⁄
4
(60.3 cm)
10¹⁄
4
(26.1 cm)
27" 
(68.6 cm)
23¹⁄
8
(58.7 cm)
25¹⁄
4
(64.1 cm)
9" (22.9 cm)
26³⁄
4
(67.9 cm)
10¹⁄
4
(26.1 cm)
30" 
(76.2 cm)
23¹⁄
8
(58.7 cm)
28¹⁄
4
(71.8 cm)
9" (22.9 cm)
29³⁄
4
(75.6 cm)
10¹⁄
4
(26.1 cm)
CABINET OPENING DIMENSIONS
Because Whirlpool Corporation includes a continues commitment to improve 
our products, we reserve the right to change materials and specifications 
without notice.
Dimensions are for planning purposes only. For complete details, 
see Installation Instructions packed with product. Specifications 
subject to change without notice.
Ref. W10713339A
03/15
ELECTRICAL CONNECTION
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. 
A time-delay fuse or circuit breaker is also recommended. It is 
recommended that a separate circuit serving only this warming drawer 
be provided.
LOCATION REQUIREMENTS
Cabinet Front View
E
D
Toe
kick
Warming
drawer
cutouts
120 volt
grounded
outlet
(or located
in adjacent
cabinet)
A
A
B
B
C
Front view
WARMING 
DRAWER 
SIZE
MINIMUM 
BETWEEN 
CUTOUTS 
(A)
CUTOUT 
HEIGHT 
(B)
MINIMUM/
RECOMMENDED 
(C)
CUTOUT  
WIDTH 
(D)
MINIMUM 
CABINET 
WIDTH 
(E)
24" 
(61 cm)
2¹⁄
2
(6.4 cm)
9¹⁄
8
(23.2 cm)
1" (2.5 cm)/  
4¹⁄
4
" (10.8 cm)
22¹⁄
2
(57.1 cm)
24" 
(61 cm)
27" 
(68.6 cm)
2¹⁄
2
(6.4 cm)
9¹⁄
8
(23.2 cm)
1" (2.5 cm)/ 
4¹⁄
4
" (10.8 cm)
25¹⁄
2
(64.8 cm)
27" 
(68.6 cm)
30" 
(76.2 cm)
2¹⁄
2
(6.4 cm)
9¹⁄
8
(23.2 cm)
1" (2.5 cm)/ 
4¹⁄
4
" (10.8 cm)
28¹⁄
2
(72.4 cm)
30" 
(76.2 cm)
Warming drawer can be installed as an indoor single or double 
installation or installed under a single oven. Two warming drawers 
under a single oven are shown.
NOTE: The warming drawer cannot be leveled after being installed.
For outdoor installation follow the cutout dimensions above. Install the 
outdoor warming drawer in a permanent fixture.
Custom Wood Drawer Front
If you plan to install a custom wood panel to match your cabinets, we 
recommend consulting a qualified cabinetmaker or carpenter. The back 
of the wood panel must be sealed to avoid moisture damage.
Page 1 of 2