KitchenAid 27" Combination Wall Oven with Even-Heat™ True Convection (lower oven) Installation Guide

Page of 16
3
 
Electrical supply junction box should be located 3"  
(7.6 cm) maximum below the support surface when the oven 
is installed in a wall cabinet. A 1" (2.5 cm) minimum diameter 
hole should have been drilled in the left rear corner of the 
support surface to pass the appliance cable through to the 
junction box.
 
Oven support surface must be solid, level and flush with 
bottom of cabinet cutout. Floor must be able to support a 
total weight (microwave and built-in oven) of 208 lbs (95 kg) 
for 27" (68.6 cm) models or 249 lbs (113 kg) for 30" (76.2 cm) 
models.
IMPORTANT: To avoid damage to your cabinets, check 
with your builder or cabinet supplier to make sure that the 
materials used will not discolor, delaminate or sustain other 
damage. This oven has been designed in accordance with 
the requirements of UL and CSA International and complies 
with the maximum allowable wood cabinet temperatures of 
194°F (90°C).
Product Dimensions
27" and 30" (68.6 cm and 76.2 cm) Ovens
B
A
C
D
E
F
27" (68.6 cm) models
A. 42
9
/
16
" (108.0 cm) overall height
B. 25
7
/
16
" (64.6 cm) recessed width
C.  41" (104.1 cm) recessed height
D. 23
1
/
4
" (59.1 cm) max. recessed 
depth
E.  27" (68.6 cm) overall width
F.  48" (121.9 cm) flexible conduit 
length measured from the 
conduit clamp located at the 
rear of the oven. Do not remove 
the conduit clamp.
30" (76.2 cm) models
A. 42
9
/
16
" (108.0 cm) overall height
B. 28
7
/
16
" (72.2 cm) recessed width
C.  41" (104.1 cm) recessed height
D. 23
1
/
4
" (59.1 cm) max. recessed 
depth
E.  30" (76.2 cm) overall width
F.  48" (121.9 cm) flexible conduit 
length measured from the 
conduit clamp located at the rear 
of the oven. Do not remove the 
conduit clamp.
Cabinet Dimensions
27" and 30" (68.6 cm and 76.2 cm) Ovens
 * 
NOTE: The cutout height can be between 41" and 41½"  
(104.1 cm and 105.6 cm) for microwave/oven combination.
Electrical Requirements
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine  
that the ground path and wire gauge are in accordance with 
local codes.
Check with a qualified electrical installer if you are not sure the 
oven is properly grounded.
This oven must be connected to a grounded metal, permanent 
wiring system.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22.1-94, Canadian 
Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and 
all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association 
1 Batterymarch Park 
Quincy, MA 02169-7471
CSA International 
8501 East Pleasant Valley Road 
Cleveland, OH 44131-5575
F
E
A
D
G
B
C
27" (68.6 cm) models
A.  27" (68.6 cm) min. cabinet width
B.  1" (2.5 cm) top of cutout to 
bottom of upper cabinet door
C. 19
1
/
4
" (48.9 cm) bottom of 
cutout to floor is recommended. 
4"-19
1
/
4
" (10.2 cm-48.9 cm) 
bottom of cutout to floor is 
acceptable.
D. 25
1
/
2
" (64.8 cm) cutout width
E. 1
1
/
2
" (3.8 cm) min. bottom of 
cutout to top of cabinet door
F. 41
5
/
16
" (105 cm)* recommended 
cutout height
G.  24" (60.7 cm) cutout depth
30" (76.2 cm) models
A.  30" (76.2 cm) min. cabinet width
B.  1" (2.5 cm) top of cutout to 
bottom of upper cabinet door
C. 19
1
/
4
" (48.9 cm) bottom of 
cutout to floor is recommended. 
4"-19
1
/
4
" (10.2 cm-48.9 cm) 
bottom of cutout to floor is 
acceptable.
D. 28
1
/
2
" (72.4 cm) cutout width
E. 1
1
/
2
" (3.8 cm) min. bottom of 
cutout to top of cabinet door
F. 41
5
/
16
" (105 cm)* recommended 
cutout height
G.  24" (60.7 cm) cutout depth