Check that the ice maker door is not flush with the 
standard cabinets to avoid problems with opening the ice 
maker door.
Choose a location where the floor is even. It is important for 
the ice maker to be level in order to work properly. If needed, 
you can adjust the height of the ice maker by changing the 
height of the leveling legs. See “Leveling.” 
Electrical Requirements
Before you move your ice maker into its final location, it is 
important to make sure you have the proper electrical 
connection:
A 115 volt, 60 Hz., AC only, 15- or 20-amp electrical supply, 
properly grounded in accordance with the National Electrical 
Code and local codes and ordinances, is required. 
It is recommended that a separate circuit, serving only your ice 
maker, be provided. Use a receptacle which cannot be turned off 
by a switch or pull chain. 
IMPORTANT: If this product is connected to a GFCI (Ground 
Fault Circuit Interrupter) equipped outlet, nuisance tripping of the 
power supply may occur, resulting in loss of cooling. Ice quality 
may be affected. If nuisance tripping has occurred, and if the 
condition of the ice appears poor, dispose of it.
Recommended Grounding Method
The ice maker must be grounded. The ice maker is equipped with 
a power supply cord having a 3 prong grounding plug. The cord 
must be plugged into a mating, 3 prong, grounding-type wall 
receptacle, grounded in accordance with the National Electrical 
Code and local codes and ordinances. If a mating wall receptacle 
is not available, it is the personal responsibility of the customer to 
have a properly grounded, 3 prong wall receptacle installed by a 
qualified electrician.
Water Supply Requirements
Check that the water supply lines are insulated against freezing 
conditions. Ice formations in the supply lines can increase water 
pressure and damage your ice maker or home. Damage from 
frozen supply lines is not covered by the warranty.
A cold water supply with water pressure of between 30 and 
120 psi (207 and 827 kPa) is required to operate the ice maker. If 
you have questions about your water pressure, call a licensed, 
qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT:
A reverse osmosis water filtration system is not 
recommended for ice makers that have a drain pump 
installed. 
For gravity drain systems only. 
The pressure of the water supply coming out of a reverse 
osmosis system going to the water inlet valve of the ice 
maker needs to be between 30 and 120 psi (207 and 
827 kPa).
If a reverse osmosis water filtration system is connected to your 
cold water supply, the water pressure to the reverse osmosis 
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
NOTE: The reverse osmosis system must provide 1 gal. (3.8 L) of 
water per hour to the ice maker for proper ice maker operation. If 
a reverse osmosis system is desired, only a whole-house 
capacity reverse osmosis system, capable of maintaining the 
steady water supply required by the ice maker, is recommended. 
Faucet capacity reverse osmosis systems are not able to 
maintain the steady water supply required by the ice maker. 
If the water pressure to the reverse osmosis system is less than 
40 to 60 psi (276 to 414 kPa):
Check to see whether the sediment filter in the reverse 
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill 
after heavy usage.
If you have questions about your water pressure, call a licensed, 
qualified plumber.
Vacation or Extended Time Without Use
When you will not be using the ice maker for an extended 
period of time, turn off the water and power supply to the ice 
maker.
Check that the water supply lines are insulated against 
freezing conditions. Ice formations in the supply lines can 
increase water pressure and cause damage to your ice maker 
or home. Damage from freezing is not covered by the 
warranty.
A. Recommended location for electrical and plumbing fixtures
B. Floor level
3
¹⁄₂
"
(8.9 cm)
9"
(22.9 cm)
11
¹⁄₂
"
(29.2 cm)
24"
(60.1 cm)
34"
(86.4 cm)
Min.
34
¹⁄₂
"
(87.6 cm)
Max.
B
A
28
¹⁄₂
"
(72.4 cm)
C
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.