Location Requirements
To ensure proper ventilation for your ice maker, the front side
 
must be completely unobstructed. The ice maker may be
 
closed-in on the top and three sides, but the installation
 
should allow the ice maker to be pulled forward for servicing
 
if necessary.
Installation of the ice maker requires a cold water supply inlet
 
of 
¹⁄₄" (6.35 mm) O.D. soft copper tubing with a shut-off valve 
or
 a Whirlpool supply line Part Number 8212547RB, and a 
Whirlpool approved drain pump, Part Number 1901A, only to
 
carry the water to an existing drain.
Choose a well
-ventilated area with temperatures above 55°F 
(13°C) and below 110°F (43°C). Best results are obtained
 
between 70°F and 90°F (21ºC and 32°C).
The ice maker must be installed in an area sheltered from 
the
 elements, such as wind, rain, water spray, or drip.
When installing the ice maker under a counter, follow the
 
recommended opening dimensions shown. Place electrical
 
and plumbing fixtures in the recommended location as
 
shown.
NOTES:
Check that the power supply cord is not damaged, 
 
pinched
, or kinked between the ice maker and the 
cabinet.
Check that the water supply line is not damaged, 
 
pinched
, or kinked between the ice maker and the 
cabinet.
Check that the drain line (on some models) is not
 
damaged, pinched
, or kinked between the ice maker and 
the cabinet.
Check that the ice maker door is not flush with the
 
standard cabinets to avoid problems with opening the ice
 
maker door. 
Choose a location where the floor is even. It is important for
the ice maker to be level in order to work properly. If needed,
you can adjust the height of the ice maker by changing the
height of the leveling legs. See “Leveling.”
Electrical Requirements
Before you move your ice maker into its final location, it is 
important to make sure you have the proper electrical 
connection:
A 115
-volt, 60 Hz., AC-only, 15- or 20-amp electrical supply, 
properly grounded in accordance with the National Electrical 
Code and local codes and ordinances, is required. 
It is recommended that a separate circuit, serving only your ice 
maker, be provided. Use a receptacle which cannot be turned off 
by a switch or pull chain. 
IMPORTANT: If this product is connected to a GFCI (Ground 
Fault Circuit Interrupter) equipped outlet, nuisance tripping of the 
power supply may occur, resulting in loss of cooling. Ice quality 
may be affected. If nuisance tripping has occurred, and if the 
condition of the ice appears poor, dispose of it.
Recommended Grounding Method
The ice maker must be grounded. The ice maker is equipped with 
a power supply cord having a 3 prong grounding plug. The cord 
must be plugged into a mating, 3 prong, grounding-type wall 
receptacle, grounded in accordance with the National Electrical 
Code and local codes and ordinances. If a mating wall receptacle 
is not available, it is the personal responsibility of the customer to 
have a properly grounded, 3 prong wall receptacle installed by a 
qualified electrician.
Water
 Supply Requirements
Check that the water supply lines are insulated against freezing 
conditions. Ice formations in the supply lines can increase water 
pressure and damage your ice maker or home. Damage from 
frozen supply lines is not covered by the warranty.
A cold water supply with water pressure of between 30 and 
120
 psi (207 and 827 kPa) is required to operate the ice maker. If 
you have questions about your water pressure, call a licensed, 
qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT:
A reverse osmosis water filtration system is not
recommended for ice makers that have a drain pump
installed.
For gravity drain systems only.
The pressure of the water supply coming out of a reverse
osmosis system going to the water inlet valve of the ice
maker needs to be between 30 and 120 psi (207 and
827 kPa).
A. Recommended location for electrical and plumbing fixtures
B. Floor level
3
¹⁄₂
"
(8.9 cm)
9"
(22.9 cm)
11
¹⁄₂
"
(29.2 cm)
24"
(60.1 cm)
15"
(38.1 cm)
34"
(86.4 cm)
Min.
34
¹⁄₂
"
(87.6 cm)
Max.
B
A
28
¹⁄₂
"
(72.4 cm)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING