KitchenAid KXW8736YSS Installation Guide

Page of 36
4
Parts needed
Home power supply cable
1 - ½" (12.7 mm) UL listed or CSA approved strain relief
3 UL listed wire connectors
1 wall or roof cap
Metal vent system
Blower motor system - internal or external (See “Blower 
Motor System” in the “Accessories” section.)
Parts supplied
Remove parts from packages. Check that all parts are included.
2 metal grease filters for 30" (76.2 cm) and 36" (91.4 cm) 
models
3 metal grease filters for 48" (121.9 cm) models
Range hood canopy with halogen lamps installed.
1 - 10" (25.4 cm) square to 10" (25.4 cm) round duct 
transition with damper
Wood support
Grease drip trays
4 - 6 x 80 mm mounting screws
4 - 3.5 x 9.5 mm screws
6 - 4.2 x 19 mm screws
2 - D5.3 x 20 mm washers
2 - 10 x 50 mm wall anchors
T-20 TORX
®†
 adapter
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial rating plate. The model/serial rating 
plate is located inside the range hood on the rear wall of the 
range hood.
Canopy range hood location should be away from strong draft 
areas, such as windows, doors and strong heating vents. 
Cabinet opening dimensions that are shown must be used. Given 
dimensions provide minimum clearance.
The canopy range hood is factory set for venting through the roof 
or through the wall. 
All openings in ceiling and wall where canopy range hood will be 
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local 
codes.
Product Dimensions
Front view 
Back view 
Optional Full-Width Duct Cover Installations
†®TORX is a registered trademark of Saturn Fasteners, Inc.
A. Knockout into terminal box
B. Top of hood
C. Wood support
D. Bottom of hood
A. Optional full-width duct cover
B. Range hood
CL
18
¹⁄₁₆
" (45.9 cm) for 48" (121.9 cm) Hood
12
¹⁄₁₆
" (30.6 cm) for 36" (91.4 cm) Hood
9
¹⁄₁₆
" (23.0 cm) for 30" (76.2 cm) Hood
18" (45.7 cm)
12" (30.5 cm)
30" (76.2 cm)
36" (91.4 cm)
48" (121.9 cm)
   3
³⁄₁₆
(8.1 cm)
6
¹⁄₂
" (16.5 cm)
25" (63.5 cm)
A
B
C
CL
18
¹³⁄₁₆
" (47.8 cm) for 48" (121.9 cm) Hood
12
¹³⁄₁₆
" (32.5 cm) for 36" (91.4 cm) Hood
9
¹³⁄₁₆
" (24.9 cm) for 30" (76.2 cm) Hood
     18" 
(45.7 cm)
D
     9
⁵⁄₈
(24.4 cm)
12"
(30.5 cm)
 18"
(45.7 cm)
12"
(30.5 cm)
A
B