Netgear M4100-50G (GSM7248v2h2) - 46‐port GE + 4 GE Combo L2 Managed Switch Administrator's Guide

Page of 353
SNTP 
262
ProSAFE M4100 Managed Switches 
show sntp server
(Netgear Switch Routing) #show sntp server
Server IP Address:    
 
    81.169.155.234
Server Type:    
 
          ipv4
Server Stratum:    
 
       3
Server Reference Id:    
 
  NTP Srv: 212.186.110.32
Server Mode:    
 
          Server
Server Maximum Entries:    3
Server Current Entries:    1
SNTP Servers        
------------
IP Address:    
 
            81.169.155.234
Address Type:    
 
          IPV4
Priority:    
 
              1
Version:    
 
               4
Port:    
 
                  123
Last Update Time:    
 
      MAY 18 04:59:13 2005
Last Attempt Time:    
 
     MAY 18 11:59:33 2005
Last Update Status:    
 
    Other
Total Unicast Requests:    
 
1111
Failed Unicast Requests:    361 
Configure SNTP
The example is shown as CLI commands and as a Web interface procedure.
CLI: Configure SNTP
NETGEAR switches do not have a built-in real-time clock. However, it is possible to use 
SNTP to get the time from a public SNTP/NTP server over the Internet. You may need 
permission from those public time servers. The following steps configure SNTP on the switch:
1. 
Configure the SNTP server IP address. The IP address can be either from the public 
NTP server or your own. You can search the Internet to locate the public server. The 
servers available could be listed in domain-name format instead of address format. In 
that case, use the ping command on the PC to find the server’s IP address. The 
following example configures the SNTP server IP address to 208.14.208.19.
(Netgear Switch) (Config)#sntp server 208.14.208.19