Netgear M5300-28G3 (GSM7328Sv2h2) - ProSAFE 24+4 Gigabit Ethernet L3 Managed Stackable Switch Software Guide

Page of 764
Multicast Routing 
466
M6100, M5300, and M7100 Series Managed Switches 
8. 
In the Go To Interface field, enter the interface in unit/slot/port format and click the Go 
button.
The entry corresponding to the specified interface is selected. 
9. 
Select the check box beside the interface for which data is to be displayed or configured.
10. 
In the Admin Mode field, select the Enable or Disable option to set the administrative 
status of IGMP on the selected routing interface. 
The default is Disable. 
11. 
In the Version field, enter the version of IGMP to configure for the selected interface. 
Valid values are 1 to 3. The default value is 3. This field is configurable only when IGMP 
Interface mode is enabled.
12. 
In the Robustness field, enter the robustness value. 
This variable allows tuning for the expected packet loss on a subnet. If you expect the 
subnet to be lossy, enter a higher number for this parameter. IGMP is robust to 
robustness variable –1 packet losses. Valid values are 1 to 255. The default value is 2. 
13. 
In the Query Interval field, enter the frequency in seconds at which IGMP host-query 
packets are to be transmitted on this interface. 
Valid values are 1 to 3600. The default value is 125.
14. 
In the Query Max Response Time field, enter the maximum query response time, in tenths 
of a second, to be advertised in IGMPv2 queries on this interface. 
The default value is 100. Valid values are 0 to 255.
15. 
In the Startup Query Interval field, enter the number of seconds between the transmission 
of startup queries on the selected interface. 
Valid values are 1 to 300. The default value is 31.
16. 
In the Startup Query Count field, enter the number of queries to be sent on startup. 
The valid values are 1 to 20. The default value is 2.
17. 
In the Last Member Query Interval field, enter the last member query interval in tenths of a 
second.