Installing the Switch
The NETGEAR Smart Switch can be installed on a flat surface or in a standard 19-inch rack.
Installing the Switch on a Flat Surface
The switch ships with four self-adhesive rubber footpads. Stick one rubber footpad on each of the
four concave spaces on the bottom of the switch. The rubber footpads cushion the switch against
shock/vibrations.
four concave spaces on the bottom of the switch. The rubber footpads cushion the switch against
shock/vibrations.
Installing the Switch in a Rack
To install the switch in a rack, use the following procedure (and refer to
). To perform
this procedure, you need the 19-inch rack-mount kit supplied with switch.
1. Attach the supplied mounting brackets to the side of the switch.
2. Insert the screws provided in the rack-mount kit through each bracket and into the bracket
mounting holes in the switch.
3. Tighten the screws with a #1 Phillips screwdriver to secure each bracket.
4. Align the mounting holes in the brackets with the holes in the rack, and insert two pan-head
screws with nylon washers through each bracket and into the rack.
Power source
Provide a power source within 6 feet (1.8 meters) of the installation location. Power
specifications for the switch are shown in Appendix A
specifications for the switch are shown in Appendix A
outlet is not controlled by a wall switch, which can accidentally turn off power to the outlet
and the switch.
and the switch.
Environmental
• Temperature - Install the switch in a dry area, with ambient temperature between 0 and
40ºC (32 and 104ºF). Keep the switch away from heat sources such as direct sunlight,
warm air exhausts, hot-air vents, and heaters.
warm air exhausts, hot-air vents, and heaters.
• Operating humidity - The installation location should have a maximum relative
humidity of 90%, non-condensing.
• Ventilation - Do not restrict airflow by covering or obstructing air inlets on the sides of
the switch. Keep at least 2 inches (5.08 centimeters) free on all sides for cooling. Be
sure there is adequate airflow in the room or wiring closet where the switch is installed.
sure there is adequate airflow in the room or wiring closet where the switch is installed.
• Operating conditions - Keep the switch at least 6 ft. (1.83 m) away from nearest
source of electromagnetic noise, such as a photocopy machine.
Table 2-1. Site Requirements (continued)
Characteristics Requirements