Netgear M4100-26-POE (FSM7226Pv1h1) - 24‐port FE + 2 GE Combo L2 Managed PoE Switch Administrator's Guide
DVLANs and Private VLANs
318
ProSAFE M4100 Managed Switches
5.
Add 1/0/16 and 1/0/7 to the private group 1.
(Netgear Switch) (Config)#interface range 1/0/16-1/0/17
(Netgear Switch) (conf-if-range-1/0/16-1/0/17)#switchport private-group 2
6.
Add 1/0/16 and 1/0/7 to the private group 2.
(Netgear Switch) (conf-if-range-1/0/16-1/0/17)#exit
Web Interface: Create a Private VLAN Group
1.
Create VLAN 200.
a. Select Switching > VLAN > Basic > VLAN Configuration. A screen similar to the
following displays.
b. Enter the following information:
•
In the VLAN ID field, enter 200.
•
In the VLAN Name field, enter VLAN200.
•
In the VLAN Type field, select Static.
c. Click Add.
2.
Add ports 1/0/6, 1/0/7, 1/0/16, and 1/0/17 to VLAN 200.
a. Select Switching > VLAN > Advanced > VLAN Membership. A screen similar to the
following displays.