Monitoring the System 
402
M4100 Series Managed Switch 
12. 
Receiver Address. The IP address of the sFlow collector. If set to 0.0.0.0 no sFlow 
datagrams are sent. 
13. 
Receiver Port. The destination port for sFlow datagrams. The allowed range is (1 to 65535). 
14. 
Click the APPLY button.
Your settings are saved.
Configure sFlow Interface Settings
The sFlow agent collects statistical packet-based sampling of switched flows and sends them 
to the configured receivers. A data source configured to collect flow samples is called a 
sampler. sFlow agent also collects time-based sampling of network interface statistics and 
sends them to the configured sFlow receivers. A data source configured to collect counter 
samples is called a poller.
To configure sFlow interface settings: 
1. 
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for 
example, 169.254.100.201.
2. 
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on 
the switch.
3. 
Launch a web browser.
4. 
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100. 
The Login screen displays.
5. 
Enter the user name and password. 
The default admin user name is admin and the default admin password is blank, that is, 
do not enter a password.
6. 
Click the Login button. 
The web management interface menu displays.