KitchenAid 30" Commercial-Style Hood Use & Care Manual

Page of 28
5
Venting Requirements
Do not terminate the vent system in an attic or other enclosed 
area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Vent system must terminate to the outside.
Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is 
recommended. Do not use plastic or metal foil vent.
The size of the vent should be uniform.
The vent system must have a damper. If roof or wall cap has a 
damper, do not use damper supplied with the range hood.
Use duct tape to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the 
cap.
Determine which venting method is best for your application.
For Best Performance:
Do not install 2 elbows together.
Use no more than three 90° elbows.
If an elbow is used, install it as far away as possible from the 
hood’s vent motor exhaust opening.
Make sure there is a minimum of 24" (61 cm) of straight vent 
between the elbows if more than one elbow is used.
The length of vent system and number of elbows should be kept 
to a minimum to provide efficient performance.
Cold Weather Installations
An additional backdraft damper should be installed to minimize 
backward cold air flow and a nonmetallic thermal break installed 
to minimize conduction of outside temperatures as part of the 
vent system. The damper should be on the cold air side of the 
thermal break.
Makeup Air
Local building codes may require the use of makeup air systems 
when using ventilation systems greater than specified CFM of air 
movement. The specified CFM varies from locale to locale. 
Consult your HVAC professional for specific requirements in your 
area.
Venting Methods
This range hood is factory set for vented installations. Vent 
system can terminate through either the roof or wall. A 
6" (15.2 cm) round vent system must be used. The vent system 
length should not exceed 35 ft (10.7 m).
Calculating Vent System Length
To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.
Example vent system
NOTE: Flexible vent is not recommended. Flexible vent creates 
back pressure and air turbulence that greatly reduce 
performance.
Option 1 - Roof Venting
Option 2 - Wall Venting
A. 6" (15.2 cm) round roof venting
B. Roof cap
A. 6" (15.2 cm) round wall venting
B. Wall cap
A
B
A
B
Vent piece
6" (15.2 cm) round
45° elbow
2.5 ft (0.8 m) 
90° elbow
5.0 ft (1.5 m)
Maximum length
= 35 ft (10.7 m)
1- 90° elbow
= 5 ft (1.5 m)
8 ft (2.4 m) straight
= 8 ft (2.4 m)
1 - wall cap
= 0 ft (0 m)
System length
= 13 ft (3.9 m)
90˚ elbow
2 ft 
(0.6 m)
6 ft (1.8 m)
wall cap