KitchenAid 2.0 cu. ft. Capacity 1,200 Watts Architect® Series II Installation Guide

Page of 12
4
INSTALLATION INSTRUCTIONS
Remove Mounting Plate
Depending on your model, the mounting plate may be in the foam 
packaging, or it may be attached to the back of the microwave 
oven.
NOTE: To avoid possible damage to the work surface, cover the 
work surface.
1. Remove any remaining contents from the microwave oven 
cavity.
2. If the mounting plate is attached to the back of the microwave 
oven, remove it and set it aside.
3. Tape the microwave oven door closed so that door does not 
swing open while the microwave oven is being handled.
NOTE: To avoid damage to the microwave oven, do not grip or 
use the door or door handle while the microwave oven is being 
handled.
Convert Microwave Oven to 
External Venting
(for wall or roof venting only)
The microwave oven is set for recirculation installation. For wall or 
roof venting, changes must be made to the venting system. See 
“Venting Design Specifications” section.
NOTE: Skip this section if you are using recirculation installation. 
Keep the damper assembly in case the venting method is 
changed, or the microwave oven is reinstalled in another location 
where wall or roof venting may be used.
To prepare the microwave oven for wall or roof venting, the vent 
deflector (L-shaped metal bar) must be installed, and the 
appropriate damper vent opening must be uncovered.
To Install Vent Deflector:
1. Gently pull the rings and lift vent screen from the top of the 
microwave oven.
2. With vent deflector oriented as shown (wide side down), slide 
it back and under the back edge of the vent opening.
3. When the vent deflector is as far back as it can easily slide, flip 
it so that the wide side is to the back of the microwave oven, 
and the narrow side (with holes) is down. The vent deflector 
holes should align with mounting holes in the vent opening, as 
shown in inset.
A. Top of microwave oven
B. Vent screen
C. Rings
B                   C
A
A. Vent opening
B. Vent deflector
A. Vent opening
B. Vent deflector
A              B
A              B