KitchenAid Top Control Tall Tub Panel-Ready Dishwasher Dimensional Illustrations

Page of 2
Undercounter Dishwasher
PRODUCT MODEL NUMBERS
UDT555SAFP
Minimum Clearances
NOTES:
 
Corner locations require 2" (5.1 cm) minimum clearance  
between the side of the dishwasher door and the wall  
or cabinet.
 
A minimum of 25
5
/
8
" (65.1 cm) is required in front of the 
dishwasher to allow the door to open fully.
 
Opening should be square, and the floor should be level.
Countertop
Dishwasher
2" (5.1 cm) min. 
clearance for door 
opening
25
5
/
8
"  
(65.1 cm)
Electrical Requirements
 
120 volt, 60 Hz, AC-only, 15 or 20 amp., fused electrical supply
 
 Copper wire only, 2-wire with ground
Recommended:
 
Time-delay fuse or circuit breaker
 
Separate circuit
Drain Requirements
 
Use the new drain hose supplied with your dishwasher. 
NOTE: If a longer drain hose is required:
 
Use a new drain hose with maximum length of 10 ft (3 m) 
that meets all current AHAM/IAPMO test standards. 
 
Use a new drain hose that is resistant to heat and detergent.
 
Use a new drain hose that fits the 1" (2.5 cm) drain 
connector on the dishwasher.
 
Connect drain hose to waste tee or disposal inlet above 
drain trap in house plumbing.
 
Connect drain hose to house plumbing 20" (50.8 cm) 
minimum above the floor. 
NOTE: It is recommended that the drain hose either be looped 
up and securely fastened to the underside of the counter, or be 
connected to an air gap.
 
Use an air gap if the drain hose is connected to house plumb-
ing lower than 18" (45.7 cm) above the subfloor or floor.
Drain Air Gap
 
Air gap
 Use 
1
/
2
" minimum I.D. drain line fittings.
NOTE: Do not connect drain lines from other devices to the 
dishwasher drain hose.
Water Supply Requirements
 
A hot water line with 20-120 psi (138-862 kPa) water pressure.
 
120°F (49°C) water at dishwasher.
 
3
/
8
" O.D. copper tubing with compression fitting or flexible 
stainless steel braided fill line 
NOTE: 
1
/
2
" minimum plastic tubing is not recommended.
 
A 90° elbow with 
3
/
8
" N.P.T. external pipe threads on one end.
IMPORTANT: Do not solder within 6" (15.2 cm) from water  
inlet valve.
Product Dimensions
2
1
/
2
"  
(6.2 cm)
24" (61 cm)* 
16
5
/
8
"  
(42.2 cm)
32
1
/
2
" to 34
1
/
2
(82.6 cm to 87.6 cm)
*To front of door frame
SIDE VIEW
23
5
/
8
"  
(59.8 cm)
REAR VIEW
Because Whirlpool Corporation policy includes a continuous commitment 
to improve our products, we reserve the right to change materials and 
specifications without notice.
Dimensions are for planning purposes only. For complete details, see 
Installation Instructions packed with product. Specifications subject to 
change without notice.
Page  1 of 2 
W10703184-D-WH
5/16