Honeywell DR90 Specification Guide

Page of 2
TrueDRY™ DR90
Ventilating Dehumidification System
SPECIFICATION DATA
68-3080-01
DR90 Capacities and Performance
Part Number: 
DR90
Blower: 
235 CFM @ 0.0 in. WG 
 
175 CFM @ 0.6 in. WG
Supply Voltage: 
120 VAC; 60 Hz.
Amps: 
6.7 A
Power transformer 
to R/C terminals:  24 VAC, 0.85A
Energy  
performance: 
2.5 liters (5.3 pints) per  
 
kilowatt hour (KWH)
Refrigerant: 
R-410A
Operating Temp Range 
(outside cabinet): 
34 – 135 ºF (1.1 – 57.2 ºC)
Capacity: 
 
47 pints/day (60 ºF [15.6 ºC], 60 %RH) 
77 pints/day (70 ºF [21.1 ºC], 60 %RH) 
90 pints/day (80 ºF [26.7 ºC], 60 %RH)
Coverage: 
Up to 2800 sq. ft.
Duct Connections: 
6 in. Supply Inlet 
 
10 in. Round Inlet 
 
10 in. Round Outlet 
 
(ABS Plastic)
Filter Efficiency: 
Standard MERV-11
Drain Connection: 
3/4 in. threaded female NPT, 
 
with attached 3/4 in. threaded 
 
male NPT
Dimensions (See Fig. 1):   
Width: 
14-3/8 in.  
Height: 
21-9/32 in. 
Length: 
33-7/16 in. (without collars) 
 
39-13/16 in. (with collars) 
Weight: 
92.2 lbs (41.9 Kg)
Shipping Specs 
  
Width: 
18-1/2 in.  
Height: 
21-1/2 in. 
Length: 
40-1/2 in. (with collars) 
Weight: 
102 lbs (46.3 Kg)
Optional Parts 
 
Compressor run capacity:   
50049536-001 
Blower Assembly: 
 
 
50027976-001 
Filter: 
 
 
50049536-003 
6–in. Duct Collar: 
 
 
50049536-004 
10-in. Duct Collar: 
 
 
50049536-005 
Magnetic door: 
 
 
50049536-006 
Compressor relay, 
    SPST, 24 VAC,30A:   
 
50035445-014 
Fan relay, SPDT, 24 VAC, 15A: 
50035445-011 
Transformer 120/24 VAC, 40VA: 
50035445-013
ETL Listed. Energy Star Rated. Conforms to UL 
Std. 474.
For more information call 1-800-468-1502 or 
visit our website at customer.honeywell.com.
The Honeywell TrueDRY DR90 ensures the home is maintained at proper 
humidity levels through its high performance and efficiency.
•  Remove up to 90 pints of water per day from the indoor air
•  Built in fresh air supply
•  Air Filtration
Dehumidification
The TrueDRY DR90 dehumidifier utilizes refrigeration and internal air cir-
culation to cool the incoming air stream below its dew point. This cooled 
and drier air is used to pre-cool the incoming air stream resulting in a 
significant increase in overall efficiency.
After helping to cool the incoming air, the processed air is reheated by 
passing through the condenser coil. The heat removed by the evapora-
tor coil is returned to the air stream, resulting in an overall temperature 
increase to the processed air. 
The TrueDRY DR90 is controlled by a variety of 24 volt remote wired con-
trols.
Fresh Air Ventilation
Optional fresh outdoor air may be ducted to the unit via a six-inch round 
duct. This provides fresh air to dilute pollutants and maintain a normal 
oxygen content in the air. The amount of fresh air ventilation can be 
regulated by a variety of dampers and controls.
Air Filtration
The TrueDRY DR90 includes air filtration to keep the DR90’s condenser 
coils clean. A MERV-11 media filter is standard.
Dimensions: 
3/4 in. (D) x 13-3/4 in. (H) x 13-3/4 in. (W)
Fig. 1. Dimensions in in. (mm).
3 3/16
(81) 
33 7/16 (849)
3 3/16
(81)
21 9/32
(541)
14 3/8 (365)
M28840