Honeywell Standard Non-Programmable Thermostat (CT5X) Owner's Manual

Page of 8
CT500 ELECTRONIC THERMOSTAT
69-1525—2
4
Fig. 6. CT500 wallplate wiring connections.
Fig. 7. CT500 methods for wiring connection.
5 MOUNT THERMOSTAT TO 
WALLPLATE
Align the tab and connector pins at the top of the 
thermostat with the wallplate. See Fig. 8. 
Fig. 8. Mounting thermostat to wallplate.
Press the thermostat straight onto the wallplate to 
latch.
NOTE: To remove the thermostat from the wallplate, 
grasp the thermostat on both sides and pull it 
straight out.
Restore power to the heating/cooling system.
6 OPERATE YOUR THERMOSTAT
Display Temperature Setting
a. Press ▼ or ▲  once to display present temper-
ature setting.
b. The temperature setpoint and the room tem-
perature are shown separately on the digital 
display. The ▼ indicator points to Set when the 
temperature setpoint is displayed and to Room 
when the room temperature is displayed.
7 SET FAN AND SYSTEM 
SWITCHES
Manually control fan and system settings using the 
switches located at the bottom of the thermostat case. 
See. Fig. 9 for switch locations.
M14874
ALTERNATE
MOUNTING
SCREW HOLE
MOUNTING
SCREW
HOLE
MOUNTING
SCREW HOLE
ALTERNATE MOUNTING
SCREW HOLE
KEEP WIRING IN
SHADED AREA
WIRING ENTRANCE HOLE
W
Y
G
R
M12537
FOR WRAPAROUND, STRIP 
7/16 IN. (11 mm)
FOR STRAIGHT INSERTION,
STRIP 5/16 IN. (8 mm)
M11025B
FAN
SYSTEM
Auto On
Cool Off Heat
DASHED LINES INDICATE TABS 
ON BACK OF THERMOSTAT
FAN
SYSTEM
Auto 
Cool Off Heat
ENGAGE TABS AT TOP 
OF THERMOSTAT WITH 
SLOTS ON WALLPLATE.
A
B
PRESS LOWER EDGE OF 
CASE TO LATCH.
Set
Room  
Set
Room  
Set
Room  
INDICATOR
ROOM TEMPERATURE
SETPOINT TEMPERATURE
M14679