If the advice does not lead to the
desired result, contact the nearest
Authorised Service Centre.
CLOSING THE DOOR
1. 
Clean the door gaskets.
2. If necessary, adjust the door. Refer to assembly
instructions.
3. If necessary, replace the defective door
gaskets. Contact the Authorised Service
Centre.
INSTALLATION
POSITIONING
Install the appliance in a dry, well ventilated indoors
where the ambient temperature corresponds to the
climate class indicated on the rating plate of the
appliance.
Climate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Some functional problems might occur
for some types of models when
operating outside of that range. The
correct operation can only be
guaranteed within the specified
temperature range. If you have any
doubts regarding where to install the
appliance, please turn to the vendor,
to our customer service or to the
nearest Authorised Service Centre.
ELECTRICAL CONNECTION
• Before plugging in, ensure that the voltage and
frequency shown on the rating plate correspond
to your domestic power supply.
• The appliance must be earthed. The power
supply cable plug is provided with a contact for
this purpose. If the domestic power supply
socket is not earthed, connect the appliance to
a separate earth in compliance with current
regulations, consulting a qualified electrician.
• The manufacturer declines all responsibility if
the above safety precautions are not observed.
• This appliance complies with the E.E.C.
Directives.
VENTILATION REQUIREMENTS
The airflow behind the appliance must be sufficient.
5 cm
min. 200cm
2
min.
200cm
2
TECHNICAL DATA
TECHNICAL DATA
 
 
 
Dimensions of the recess
 
 
Height
mm
1780
Width
mm
560
Depth
mm
550
Rising time
Hours
24
20