. Handle
4.1 Hot-water output
●Press the power button on the control panel to turn the LCD on. The screen flashes to show 
42℃ for 3 seconds (Default temperature setting). 
●Open the hot-water faucet, the burner inflames automatically and hot water flows out. (For the first 
 running, open and close the hot-water faucet repeatedly till water heater inflames, to discharge air 
 residue in the gas pipe.)
●The faucet is recommended to be turned to large extent. Otherwise ignition may be unavailable, or
it may be flameout during the cold-water mixing process.
●The water heater adopts new safe and gas-saving technology. Gas will be cut off automatically after
water heater works for 45±3min without interruption. Then burner is extinguished. If more service is 
required, just close the faucet for several seconds and restart, re-ignition will be available then. 
8
4.2 Water temperature adjustment
●If both control panel and wireless remote controller are connected with water heater, please confirm if
priority indication lamp is on.
Adjustment by 
control panel
Adjustment by 
wireless remote
controller
If priority indication on 
the control panel turns 
bright 
If priority indication on 
the control panel does 
not turn bright 
If priority indication on 
the control panel turns 
flashing 
If priority indication on 
the wireless remote
 controller turns bright 
If priority indication on 
the wireless remote
controller does not 
If priority indication on 
the wireless remote
controller flashes
●Control panel is given priority. It’s allowed to 
start/stop water heater, adjust the water 
temperature, set water flux and etc.
●Remote controller is given priority. Therefore 
temperature adjustment is not available for the 
control panel. User can only read the 
temperature, however, on/off button still works.
●Start/stop the water heater with on/off button 
to get the priority. Then priority indication turns 
bright.
●Remote controller is given priority. Water 
temperature adjustment is locked at this time,
because hot water is being used. User can only 
read the temperature, however, water flux 
setting still works. 
●In such case it is impossible for the control 
panel to get priority. On/off button is invalid.
●Remote controller is given priority. It’s allowed
to start/stop water heater, adjust the water 
temperature, set water flux and etc.
●If hot water is not working, tap the priority
button then the priority icon disappears. 
Meanwhile control panel is given priority.
●Control panel or other remote controller is 
given priority. Adjustment buttons are locked,
user can only read the temperature. And other
function buttons are invalid, too. On/off button
can only start or stop remote controller but not
water heater.
●Tap the priority button to get priority. Start 
setting and/or adjustment till priority icon
shows up.
●Control panel or other remote controller (if 
more than one remote controllers are mounted) 
is given priority. Adjustment buttons are locked
because hot water is working. At this time, user 
can only read the temperature. And other
functions are unavailable, too. On/off button
can only start or stop remote controller but not
water heater.
●In such case it is impossible to get priority.
●Temperature setting range of water heater is 35-70℃. When temperature is within 35-48℃,tap the
temperature setting button to increase or decrease temperature, it actually switches by 1℃/tap.
Right after the completion of temperature setting, temperature icon flashes for 3 sec and then stays still. 
If temperature is within 50-70℃, tap the temperature setting button to increase or decrease the 
temperature by 5℃/tap. And when temperature setting completes, temperature icon flashes for 10 sec 
and then stays still.
turn bright