Cisco Cisco Catalyst 6000 Multilayer Switch Feature Card MSFC2 Data Sheet
© 2005 Cisco Systems, Inc. All rights reserved.
Important notices, privacy statements, and trademarks of Cisco Systems, Inc. can be found on cisco.com.
Page 9 of 13
ORDERABILITY, AVAILABILITY, COMPATIBILITY, MINIMUM SOFTWARE, AND MEMORY REQUIREMENTS
Table 4.
Product Specifications/Regulatory Approvals Part Number NM-AIC-64(=
Features
Description
Network Module Density
•
64 discrete alarm points
–
Up to 8 of the last 64 alarm points can be configured to accept analog or discrete inputs.
•
16 relay control points
Cisco IOS Release
Cisco IOS 12.2 (2) XG and higher
Voltage Range Discrete Points
-36V to -72V
Analog Input Modes
Current sense or voltage sense
Voltage Sense Range—Analog Input
-60V to 60V
Current Sense Range
0 to 20 mA
Number of Network Modules
Supported
Supported
•
Cisco 366x—Six network modules or 384 contact points, and 96 relay controls
•
Cisco 3640—Three network modules or 192 contact points, and 48 relay controls
•
Cisco 3631—Two network modules or 128 contact points, and 32 relay controls
•
Cisco 26xx—One network module or 64 contact points, and 16 relay controls
Alarm Message Formats/Protocols
Supported
Supported
Configurable—TL-1 (two sessions) or SNMP (four sessions) Alarm messages can be sent autonomous
or upon being polled.
or upon being polled.
Connector Types
Four SCSI II Micro DB-50 female connectors
Recommended Patch Panels and
Cables (See Table 1)
Cables (See Table 1)
AIC-DBL-PNL, AIC-SGL-PNL, CAB-AIC-008
MIB Support
CISCO-AIC-MIB
Online Insertion and Removal (OIR)
Support
Support
Yes, on Cisco 366x 3745, and 3845 only
Standards and Compliance Support
Dimensions (H x W x D) 1.55 x 7.10 x 7.2 in.
Weight
1.1 lb maximum
Environmental Conditions
•
Operating temperature: +32° to +104° F (0° to +40° C)
•
Nonoperating temperature: 13° to +158° F (25° to +7 0° C)
Power Requirements
10.7 watts
Maximum Relative Humidity
5 to 95 percent
Mean Time Between Failures (MTBF)
113,772 hours at 25° C ambient conditions
Emissions
•
CISPR22:1997 [EN55022:1998] Class A 0.15-30MHz [dBuV/dBuA] Conducted Emissions
•
CISPR22:1997 [EN55022:1998] Class A 30MHz-1GHz [dBuV/m] Radiated Emissions
Immunity
•
EN61000-4-2: 1995 Level 3 6kV Contact,8kV Air ESD
•
EN61000-4-3: 1997 Level 3 10V/m Radiated RF Susceptibility
•
EN61000-4-4: 1995 Level 4 2kV Burst/Transients
•
EN61000-4-4: 1995 Level 4 4kV Burst/Transients
•
EN61000-4-5: 1995 - 0.5kV/0.5kV Surges
•
EN61000-4-6: 1996 Level 3 10V Conducted RF Susceptibility
•
AS/NZS 3548: 1995 incorporating Amendments 1 and 2
•
VCCIV-3/ 97.04
•
47 CFR 15 Subpart B: 1998