Cisco Cisco Prime Optical 10.6 Developer's Guide

Page of 665
Cisco Prime Optical 10.6 GateWay/CORBA Programmer Reference Guide 
 
 
206
 
 
This interface is also supported for the attribute LinkIntegrityTimer for the cards and the NE types listed 
in the following table. 
Card 
ONS 15454 SONET  ONS 15454 SDH 
G1000_4 
CE-1000-4  X 
 
For CE-100T-8, CE-MR-6, and CE-MR-10 cards, the LinkIntegrityTimer attribute value cannot be set to 
0. 
For G1000_4 and CE-1000-4 cards, the LinkIntegrityTimer attribute value cannot be set to 0 if the 
LinkIntegrityDisable attribute is set to false. 
For G1000_4 and CE-1000-4 cards, the LinkIntegrityTimer attribute value must be set to 0 if the 
LinkIntegrityDisable attribute is set to true. 
For G1000_4 and CE-1000-4 cards, the LinkIntegrityDisable attribute can be set only to true or false. 
For CPT 200, CPT 200 SDH, CPT 600, and CPT 600 SDH, additional connectionless TP information can 
be set. For more information, see 
. 
This operation returns a list of modified attributes with the new related values applied. 
Parameters 
Name 
Type 
Input/ 
Output 
Description 
tpName 
globaldefs::NamingAttributes_T  In 
Name of the TP to which to apply the list 
of modified attribute values. 
additionalInfo  globaldefs::NVSList_T 
In/out 
List of attributes that must be modified, 
as well as the new related values to 
apply. 
Throws 
Compliance 
TMF-defined. 
3.8.15  getTP 
Synopsis 
Description 
This interface returns the TP structure for a specific TP name. 
For the PTP on protection equipment in a 1_FOR_N protection group, Prime Optical reports only the 
AlarmReporting for the LayeredParameters of that PTP.