This interface is also supported for the attribute LinkIntegrityTimer for the cards and the NE types listed
in the following table.
Card
ONS 15454 SONET ONS 15454 SDH
G1000_4
X
X
CE-1000-4 X
X
For CE-100T-8, CE-MR-6, and CE-MR-10 cards, the LinkIntegrityTimer attribute value cannot be set to
0.
For G1000_4 and CE-1000-4 cards, the LinkIntegrityTimer attribute value cannot be set to 0 if the
LinkIntegrityDisable attribute is set to false.
For G1000_4 and CE-1000-4 cards, the LinkIntegrityTimer attribute value must be set to 0 if the
LinkIntegrityDisable attribute is set to true.
For G1000_4 and CE-1000-4 cards, the LinkIntegrityDisable attribute can be set only to true or false.
For CPT 200, CPT 200 SDH, CPT 600, and CPT 600 SDH, additional connectionless TP information can
be set. For more information, see
This operation returns a list of modified attributes with the new related values applied.
Parameters
Parameters
Name
Type
Input/
Output
Output
Description
tpName
globaldefs::NamingAttributes_T In
Name of the TP to which to apply the list
of modified attribute values.
of modified attribute values.
additionalInfo globaldefs::NVSList_T
In/out
List of attributes that must be modified,
as well as the new related values to
apply.
as well as the new related values to
apply.
Throws
Compliance
TMF-defined.
TMF-defined.
3.8.15 getTP
Synopsis
Description
This interface returns the TP structure for a specific TP name.
For the PTP on protection equipment in a 1_FOR_N protection group, Prime Optical reports only the
AlarmReporting for the LayeredParameters of that PTP.
This interface returns the TP structure for a specific TP name.
For the PTP on protection equipment in a 1_FOR_N protection group, Prime Optical reports only the
AlarmReporting for the LayeredParameters of that PTP.