Cisco Cisco Prime Optical 10.6 Developer's Guide

Page of 665
Cisco Prime Optical 10.6 GateWay/CORBA Programmer Reference Guide 
 
 
269
 
Parameters 
Name 
Type 
Input/ 
Output 
Description 
vcatName  globaldefs::NamingAttributes_T  In 
Name of the VCAT SNC. 
isForward  Boolean 
In 
Boolean variable used to determine the 
direction in which the member SNCs of the 
VCAT are deleted. 
Throws 
Compliance 
Prime Optical-defined. 
3.9.31  getValidSubnetworkConnectionsForMerge 
Synopsis 
Description 
This interface is used to get the list of SNCs for the Merge operation. The SncFilterCriteria specifies the 
SNCs that are requested. These SNCs are lined up. The master SNC name specifies the name of the SNC 
with which the candidates will merge. The how_many parameter provides the list of SNCs that will be 
returned. 
  The valid SncUpgradeInfo value supported by GateWay/CORBA is Merge. The valid 
SncFilterCriteria value supported by GateWay/CORBA is LINED_UP. The available values that will 
be supported in the future are listed in the ENUM definitions in the following table. 
Parameters 
Name 
Type 
Input/ 
Output  Description 
details 
multiLayerSubnetwork::SncUpgr 
adeInfo_T 
In 
Upgrade info for which the list 
of SNCs is requested. Available 
values are: 
• 
Merge
 
• 
Reconfigure
 
  Prime Optical supports only