Secondary States (SST) 
Attribute Value 
Meaning 
Maintenance (MT) 
The entity has been manually removed from service for 
maintenance. It is still capable of performing its provisioned 
functions. Traffic is still carried. 
Disabled (DSBLD) 
The entity has been manually removed from service and cannot 
perform its provisioned functions. All of its provisioned services 
are disrupted. Traffic is not carried. 
Loopback (LPBK) 
The loopback command is in effect (any loopback type).  
 
2.1.6.3 
XTC Cards 
The XTC-14 card has 14 DS1 ports numbered 1 through 14. Only VT1.5 SNCs can be created on these 
ports. The XTC-28-3 card has 28 DS1 ports numbered 1 through 28 and 3 DS3 ports numbered 29 
through 31. VT1.5 SNCs can be created on DS1 ports, and STS-1 SNCs can be created on DS3 ports. 
2.1.6.4 
PTPs 
All PTPs are bidirectional for the ONS 15327. The ports are always in channelized mode. PTPs support 
In Service, Out of Service, Out of Service–Maintenance, and Auto in Service values for the service state 
attribute. 
2.1.6.5 
CTPs 
All CTPs are in channelized mode for the ONS 15327. Alarm monitoring cannot be turned on or off for 
CTPs. 
2.1.6.6 
SNCs 
XTC cards perform STS and VT1.5 switching. The XTC cards support the total rearrangement of 192 
bidirectional STSs from the four high-speed slots (1 to 4), plus 12 bidirectional STSs for XTC module 
low-speed electrical interfaces. The XTC VT1.5 matrix supports the grooming of 336 bidirectional VT1.5 
circuits.  
The SNC name cannot exceed 48 characters. 
2.1.6.7 
Autodiscovery 
ONS 15327 autodiscovery is identical to ONS 15454 SONET autodiscovery, described in 
. 
2.1.7  ONS 15454 SDH 
See th
 for the ONS 15454 SDH software releases that Prime 
Optical 10.6 supports. 
2.1.7.1 
Shelves 
All supported ONS 15454 SDH NEs have exactly one shelf each, with the exception of the ONS 15454 
SDH multiservice transport platform (MSTP) R7.0, which can have up to eight shelves per NE. 
2.1.7.2 
Slots 
The ONS 15454 SDH has one shelf view supplemented with the top subrack Electrical Facility 
Connection Assembly (EFCA) shelf and bottom subrack chassis. The main shelf has 17 slots numbered 1 
to 17 and contains cards that carry traffic. The EFCA shelf has 12 additional slots numbered 18 to 29 and 
contains Front Mount Electrical Connection (FMEC) modules, the ALM/PWR/MIC (A/P/M) module, and 
the CRFT/TMG/MIC (C/T/M) module. The Timing Communications and Control-International (TCC-I)