Cisco Cisco Prime Optical 10.6 Developer's Guide
Cisco Prime Optical 10.6 GateWay/CORBA Programmer Reference Guide
45
Layer
Type
Layer Rate
Value
Comments
LR_ISC3_STP_1G
10006
—
LR_ISC3_STP_2G
10007
—
LR_AUTO
10008
—
2.2.2 Inventory
The ONS 15310 CL, ONS 15310 MA SONET, ONS 15310 MA SDH, ONS 15327, ONS 15600 SONET,
and ONS 15600 SDH are single-shelf NEs. However, in future they may be expanded to multishelf,
multibay NEs. Considering this, Prime Optical reports the following:
and ONS 15600 SDH are single-shelf NEs. However, in future they may be expanded to multishelf,
multibay NEs. Considering this, Prime Optical reports the following:
• Rack = 1 and shelf = 1 for ONS 15310, ONS 15327, ONS 15600 SONET, and ONS 15600
SDH inventory. This implementation allows Prime Optical to accommodate future changes
quickly.
quickly.
• ONS 15454 MSTP NEs support up to eight shelves per NE. The shelf ID identifies a specific
shelf on the NE. The rack ID remains 1 for all shelves.
• For the ONS 15454 SDH, the EFCA shelf and the main shelf are considered to be a single
logical shelf with slots numbering from 1 to 29.
• For the ONS NCS2K SDH and ONS NCS2K SONET, the EFCA shelf and the main shelf are
considered to be a single logical shelf with slots numbering from 1 to 29.
• Rack = 1 and shelf = 1 for ONS 15216 NEs.
• For the ONS 15216 DCU, Prime Optical reports the DCU chassis as the shelf. Prime Optical
• For the ONS 15216 DCU, Prime Optical reports the DCU chassis as the shelf. Prime Optical
reports two slots as equipment holders contained by the shelf. Any DCM module is reported
as equipment under the slot.
as equipment under the slot.
• For the ONS 15216 FlexLayer, Prime Optical reports the FlexLayer chassis as the shelf.
Prime Optical reports four slots as equipment holders contained by the shelf. Any
provisioned module is reported as equipment under the slot.
provisioned module is reported as equipment under the slot.
• For the remaining ONS 15216 NEs, Prime Optical reports only one type of equipment under
the shelf. The equipment name is the same as the NE name.
• For some supported NEs, equipment does not fit in the normal equipment holders (rack,
shelf, slot, and so on) and does not have provisioning functions. For inventory purposes,
Prime Optical defines a special EquipmentHolder named AdditionalHolder to hold this
equipment.
Prime Optical defines a special EquipmentHolder named AdditionalHolder to hold this
equipment.
• For the ONS 15454 SONET R3.4 and later, the Alarm Interface Extension (AIE) is reported
in AdditionalHolder 1 (if installed). The Alarm Extension Panel (AEP) is reported in
AdditionalHolder 2.
AdditionalHolder 2.
• For the ONS 15454 SDH R3.4 and later, the AIE (if installed) is reported in
AdditionalHolder1.
• For the ONS 15600 SONET R5.0 and later, pluggable port modules (PPMs) and pluggable
I/O modules (PIMs) on ASAP cards are reported as subslots and port holders, respectively.
• For the ONS 15600 SDH R8.0, PPMs and PIMs on ASAP cards are reported as subslots and
port holders, respectively.
• For unmanaged NEs, Prime Optical reports only ManagedElement. Prime Optical does not
report any equipment holder or equipment.
• For storage NEs, Prime Optical reports only ManagedElement. Prime Optical does not report
any equipment holder or equipment.
• For M2 NEs, Prime Optical reports the slots with a provisioned card as equipment holders;
this is applicable only to slots 1 to 3. Other equipment is not managed.