Cisco Cisco D9824 Advanced Multi Decryption Receiver Installation Guide

Page of 388
 
 
 
Setup Menu 
 
OL-29015-01 
97 
 
Menu Item 
Description 
Parameters 
Mode 
Sets the tone sequence mode. 
* - Start tone only 
# - End tone only 
*/# - Start and end tones. The end 
tone is signaled after waiting the time 
specified in Delay(sec). 
Delay(sec) 
If the Mode was set to */# 
(Start/Stop), set the delay, in 
seconds, between the start and 
stop sequences. 
1 to 255. The default is 30. 
Relay Mode 
The relay can be programmed 
to respond to an alarm or 
warning state, or the state of 
one of the eight cue trigger 
pins. The response is generated 
at the Cue Tone/Relay output 
on the rear panel of the 
receiver. 
Alarm or Trigger 
The following table displays the 
possible field settings and their 
relationship to the receiver output: 
Relay 
Mode 
Condition 
Relay 
Contact 
NC-
C-No 
Alarm  Unit Power 
Off 
Open
 
 
Close 
Alarm State  Open  Close 
No Alarm 
Close  Open 
Trigger  Active 
(selected in 
PNC) 
Close  Open 
Inactive 
Open  Close 
 
Cue Trigger Bit 
If the Relay Mode was set to 
Trigger, select the cue trigger 
bit/pin that will activate the 
relay. 
1 to 8 
Cue Tone Test 
Sets the three digit cueing tone 
test sequence. 
000 to 999 
Mode 
Sets the test sequence mode. 
* - Start tone  
# - End tone 
Run Test 
Select and press continue to run 
the cue tone test according to 
the Cue Tone Test and Mode.