Setting up Input Information 
 
OL-29015-01 
167 
 
Each record customizes the PID or stream type to decrypt. The Index number is a 
read only field that indicates the record number. You can maintain up to 64 records, 
32 records for each CAM. 
To insert a new record, click Add Row. A new row appears at the top of the table 
(see below). 
 
There are various configurations when creating a new record. The following table 
summarizes the various methods: 
If you set by 
Parameter Settings 
PID ID 
Set Mode to PID and enter PID number. 
Stream Type 
Set Mode to Stream, select Stream Category (AUD, VID, SUBT, TTX, 
or USER) and enter Stream Instance of the stream type. 
There is an additional configuration if you select user as the Stream 
Category (see below). 
Stream Type: User 
Set Mode to Stream, Stream Category to User, manually enter the 
stream code in Stream Type Value, and then the Stream Instance of 
the stream type. 
If you know the PID number, ensure that PID is selected under Mode and enter the 
appropriate PID number. Click Save
To enter the stream type, choose Stream from the Mode drop-down list, choose the 
stream type from the Stream Category (VID, AUD, SUBT, USER, or TTX) and enter 
the instance of the stream type in Stream Instance field. You can enter a range from 
1 to 64. Click Save
If you do not know the stream type, you can specify a specific hex value as the 
stream type. Choose Stream from the Mode drop-down list, choose User from the 
Stream Category drop-down list, enter the hex value of the stream in the Stream 
Type Value
 field and the instance of the customized stream type in Stream Instance 
field. You can enter a two digit hexadecimal value for the Stream Type and a range 
from 1 to 64 for the Stream Instance. Click Add