Indoor/outdoor unit installation diagram
Maximum 
allowable piping 
elevation 10m 
or less
6m or 
less
Install S-trap for 
every 6m
Maximum allowable 
piping length 20m 
or less
Outdoor unit
50cm 
or more
30c
m o
mo
re
50cm or 
more
Air guide
(Not provided by 
manufacturer )
30cm or more
20cm or more
No 
obs
tacl
1m
 or m
ore 
60cm
 or m
ore
30cm or 
more
Protection 
vinyl
Outdoor 
unit leg
Rubber leg
Spare space for piping
•  One S-trap must be installed on the low pressure 
pipe up to 6m of piping elevation. For piping 
elevation that exceeds 6m, install S-trap every 
6m.
CAUTION
Piping length for indoor/outdoor unit installation
f
f Refer to illustration on the left for maximum allowable 
piping length and elevation.
f
f Since product performance and lifespan may decrease as 
piping length becomes longer, try to minimize the piping 
length but make sure it is over 5m.
f
f Select the installation location where you can keep the 
piping bending to maximum 10 spots.
f
f Stated cooling performance is based on product with 5m 
piping.
Installation space for floor type indoor unit
f
f To minimize the waste of space due to  installation, install the indoor unit as 
shown in below figure.
 - Top view
After completing the installation, remove the protection vinyl. 
(Be careful of static electricity).
After completing the installation, remove the protective 
filament film on the product.
•  Make sure that there are no obstacles (such as curtains etc.) blocking air 
inlets of the indoor unit. 
•  Clear space on the right side of the indoor unit for possible filter 
maintenance in the future.
CAUTION
When air guide needs to be installed to prevent the warm discharge air from 
disturbing the pedestrian, refer to the illustration on the right side for installation.