Electrical work
•  The electrical work should be performed by a specialist qualified for the work.
•  Avoid using multi-concent but use rate power supply for air conditioner. (Use separate power cable for outdoor 
unit.)
CAUTION
Wiring standard
f
f Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in 
compliance with current local safety standards.
f
f Make sure to install exclusive power supply(purchase separately).
 - If you use multiple connecting, there is a risk of electric  shock or fire.
f
f If the outdoor power supply has been selected, install circuit breaker (ELCB). (Purchased separately)
f
f Make sure to connect earth wire.
Type
Indoor unit
Indoor power (Indoor/outdoor unit power cable)
Outdoor unit
Outdoor power (Earth leakage circuit breaker)
Power
1Ph, 220~240V, 50Hz/60Hz
Circuit breaker
20A
Indoor/outdoor unit power cable
1.0mm
2
 or more
Outdoor unit power cable
2.5mm
2
 or more
Indoor/outdoor unit communication cable
0.75mm
2
 or more
Connecting procedure
1.  After loosening the 4 screws(
①) of support-inlet, disassemble the support-inlet. 
2.  Connect the housings of communication cable(
②) for an indoor unit and outdoor unit.
3.  Fix the power connection cable and communication cable with a cable clamp.
4.  After assembling the SUPPORT-INLET and fix it with the screws(
①).
COVER-PCB
Screw 
SUPPORT- 
INLET
 
Power connection 
cable
Communication 
cable
Earth plate
Power terminal
Cable clamp
Housing 
사우디,인도,나이지리아향 FAC MEMORY 냉방_IBIM_EN_04773A-00.indd   46