Electrical work
• The electrical work should be performed by a specialist qualified for the work.
• Avoid using multi-concent but use rate power supply for air conditioner. (Use separate power cable for outdoor
• Avoid using multi-concent but use rate power supply for air conditioner. (Use separate power cable for outdoor
unit.)
CAUTION
Wiring standard
f
f Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in
compliance with current local safety standards.
f
f Make sure to install exclusive power supply(purchase separately).
- If you use multiple connecting, there is a risk of electric shock or fire.
f
f If the outdoor power supply has been selected, install circuit breaker (ELCB). (Purchased separately)
f
f Make sure to connect earth wire.
Type
Indoor unit
Indoor power (Indoor/outdoor unit power cable)
Outdoor unit
Outdoor power (Earth leakage circuit breaker)
Power
1Ph, 220~240V, 50Hz/60Hz
Circuit breaker
20A
Indoor/outdoor unit power cable
1.0mm
2
or more
Outdoor unit power cable
2.5mm
2
or more
Indoor/outdoor unit communication cable
0.75mm
2
or more
Connecting procedure
1. After loosening the 4 screws(
①) of support-inlet, disassemble the support-inlet.
2. Connect the housings of communication cable(
②) for an indoor unit and outdoor unit.
3. Fix the power connection cable and communication cable with a cable clamp.
4. After assembling the SUPPORT-INLET and fix it with the screws(
4. After assembling the SUPPORT-INLET and fix it with the screws(
①).
COVER-PCB
Screw
①
SUPPORT-
INLET
Power connection
cable
Communication
cable
Earth plate
Power terminal
Cable clamp
Housing
②