Datalogic Scanning Matrix-1000 User Manual

Page of 62
INSTALLATION 
19
 
2.3.4 Input 
 
An opto-coupled and polarity insensitive input is available on the 25-pin connector. 
The pinout is the following:  
 
Pin Name 
Function 
18 
EXT_TRIG A 
External trigger (polarity insensitive) 
19 
EXT_TRIG B 
External trigger (polarity insensitive) 
 
When current flows through the EXT_TRIG input, the yellow LED (Figure A, 6) is on. 
 
The External Trigger can be used in One Shot Mode or in Phase Mode. Its main 
functions are: 
• 
acquisition trigger in One Shot Mode 
• 
phase-ON/phase-OFF command in Phase Mode 
• 
match code storage command. 
 
This input can be driven by either a PNP or NPN type command. The connections 
are indicated in the following diagrams: 
 
 
NOTE 
Polarity insensitive input assure full functionality even if pins A and B 
are exchanged. 
 
USER INTERFACE 
OUT
MATRIX 
V
CC
 
A
Vext 
B
GND 
V
+
~
 
~
+
 
-
 
in
 
30 Vdc Max.
 
Figure 17 - Input PNP Command Using External Power