Aeg Electrolux 2110 User Manual

Page of 3
• 
The Unit can be
used with most
two stage heat
and one stage
cool heat pump
systems. 
It cannot be
used with 120 volt
heating systems. Ask your
dealer for other LUX ther-
mostats to control those
systems.
•  The Unit is programma-
ble. There are four pro-
gramming periods per day.
Each period can be pro-
grammed separately.
•  You can use the built-in
time/temperature pro-
grams, or alter them to
suit your schedule. 
The
Unit provides separate
programming for every
day of the week- for both
heating and cooling. You
can override the
programmed temperatures for as little as one programming period or for an entire vacation.
•  In cool weather, when the system switch is set to HEAT, the Unit will maintain cooler “set back”
room temperatures to save energy.  It will then change to warmer “comfort” settings —  all
automatically, at specified times during the day.
•  In warm weather, when the system switch is set to COOL, the Unit will maintain warmer “set
back” room temperatures to save energy. It will then change to cooler “comfort” settings - all
automatically, at specified times during the day.
•  A large liquid crystal display shows time, day of the week, and room and set temperatures.
It will remind you when the filter should be changed in your blower and track your system’s
energy usage. 
•  Temperature swing adjustment  lets you fine-tune your system for maximum comfort and
economy. 
•  A 4-minute minimum on/off time in COOL prevents your air conditioning system from being
damaged.
•  Two “AA”  batteries (not included) are used to retain your time and 
temperature programs.
LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA
43314
Rev C
I M P O R T A N T !
Thank you for your confidence in our product. To obtain the best results from
your investment, please read these instructions and acquaint yourself with
your purchase before installing your new thermostat. Then follow the installa-
tion procedures, one step at a time.  This will save you time and minimize the
chance of damaging the thermostat and the systems it controls.
These instructions may contain information beyond that required for your par-
ticular installation. Please save for future reference.
READ
INSTALLATION
INSTRUCTIONS
FIRST
C
A
U
T
I
O
N
• Your thermostat is a precision instrument. Please handle it with care. 
• Turn off electricity to the appliance before installing or servicing thermostat or any part
of the system. Do not turn electricity back on until work is completed. 
• Do not short (jumper) across electric terminals at control on furnace or air conditioner
to test the system. This will damage the thermostat and void your warranty. 
• All wiring must conform to local codes and ordinances. 
• This thermostat is designed for use with 24 volt and millivolt systems. The thermostat
should be limited to a maximum of 1.0 amps; higher amperage may cause damage
to the thermostat. If you are in doubt, call your utility company. 
605/2110 SERIES
PROGRAMMABLE 
HEAT PUMP THERMOSTAT
Complete, Easy To Read 
Programming And Installation
Instructions Inside
Instrucciones Completas y Fáciles 
de Leer Para Su Programación 
E Instalación Incluídas Dentro
HEAT
OFF
COOL
AUTO
ON
FAN
RESET
HOLD
NEXT
RUN
AIR
FILTER
SET
SUNDAY
PROGRAM
SET
SATURDAY
PROGRAM
SET
WEEKDAY
PROGRAMS
SET
DAY/TIME
DOWN
UP
MO
DAY
HEAT
PM
SIMPLIFIED INSTRUCTIONS
• Press UP/DOWN to set time.
TO SET PROGRAMS
• Rotate Dial to SET
WEEKDAY,
SATURDAY or
SUNDAY PROGRAM.
• Press UP/DOWN to adjust
start time.
• Press NEXT.
• Press UP/DOWN to adjust
temperature.
• Press NEXT.
• Repeat as needed or rotate
dial to RUN to stop Programming.
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
the start tf the next period.
TEMPERATURE HOLD
• Press HOLD. Adjust temperature as
desired with UP/DOWN.
•To clear, press HOLD again.
Need Help? Call 1-800-421-1130
Rotate the
dial to the
RUN
position
to close the
door.
EMER
PROGRAM
REVIEW
TO SET TIME & DAY
• Rotate Dial to SET
DAY/TIME.
• Press UP to change
current day.
• Press NEXT.
Patent No. 5,673,850
The Active Program Period
Liquid Crystal 
Display
Fan
Switch
System
Switch
Easy to 
follow 
instructions
Programming 
Dial
Thermostat
Body
The Set 
Temperature
Thermostat 
Cover
Program Review Button
HEAT
OFF
COOL
AUTO
ON
FAN
RESET
HOLD
NEXT
RUN
FILTER
SET
SUNDAY
PROGRAM
SET
SATURDAY
PROGRAM
SET
WEEKDAY
PROGRAM
SET
DAY/TIME
DOWN
UP
1500
P a t e n t s   P e n d i n g
MO
DAY
HEAT
PM
SIMPLIFIED INSTRUCTIONS
• Press UP/DOWN to set time.
TO SET PROGRAMS
• Rotate Dial to SET
WEEKDAY
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
the start tf the next period
TO SET TIME & DAY
• Rotate Dial to SET
DAY/TIME.
• Press UP to change
rr
t d
HEAT
OFF
COOL
AUTO
ON
FAN
RESET
HOLD
NEXT
RUN
FILTER
SET
SUNDAY
PROGRAM
SET
SATURDAY
PROGRAM
SET
WEEKDAY
PROGRAM
SET
DAY/TIME
DOWN
UP
1500
P a t e n t s   P e n d i n g
MO
DAY
HEAT
PM
SIMPLIFIED INSTRUCTIONS
• Press UP/DOWN to set time.
TO SET PROGRAMS
• Rotate Dial to SET
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
TO SET TIME & DAY
• Rotate Dial to SET
DAY/TIME.
• Press UP to change
DOWN
UP
MO
DAY
HEAT
PM
Choose Heat or Cool
Escoja Calentar O Enfríar
Set Day & Time
Programe el día y la hora
Installs Easily
Fácil de Instalar
Easy as
1–2–3
INSTALLATION AND OPERATING INSTRUCTIONS
FEATURES
INSTALLATION
Please read all instructions carefully
before beginning installation.
TOOLS REQUIRED
#1 Phillips screwdriver (small)
Drill with 3/16-in. (4.8mm) bit
THERMOSTAT LOCATION
On replacement installations, mount the
new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new
installations, follow the guidelines listed below.
1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is
used often. 
2. Do not install it where there are unusual heating conditions, such as: in direct 
sunlight; near a lamp, radio, television, radiator, register, or fireplace; near hot water pipes in a wall;
near a stove on the other side of a wall. 
3. Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in
a draft from a stairwell, door, or window. 
4. Do not locate in a damp area. This can lead to corrosion that will shorten 
thermostat life.
5. Do not locate where air circulation is poor, such as: in a corner or an alcove; or behind an open
door. 
6. Do not install the unit until all construction work and painting has been completed. 
7. This thermostat does not require leveling.
C A U T I O N
To avoid electrical shock and 
to prevent damage to the
furnace, air conditioner, and 
thermostat, disconnect the power
supply before beginning work. This
can be done at the fuse box, at the
circuit breaker, or at the appliance.
OFF
REMOVING THE OLD THERMOSTAT
Switch electricity to the furnace and air conditioner OFF; then pro-
ceed with the following steps. 
1. Remove cover from old thermostat. Most are snap-on types
and simply pull off. Some have locking screws on the side.
These must be loosened.
2. Note the letters printed near the terminals. Attach labels
(enclosed) to each wire for identification. Remove and label
wires one at a time. Make sure the wires do not fall back inside
the wall.
3. Loosen all screws on the old thermostat and remove it from the
wall.
MOUNTING THE UNIT ON THE WALL
1. Strip insulation 3/8 in. (9.5mm) from wire ends and clean off any corrosion.
2. Fill wall opening with non-combustible insulation to prevent
drafts from affecting the thermostat.  
3. Press up on the button on bottom of thermostat and swing the
body away from the base and up to remove the body from the
base.
C A U T I O N
Read instructions carefully
before removing any
wiring from existing 
thermostat. Wires must be
labeled before they are
removed. When removing
wires from their terminals,
ignore the color of the
wires since these may not
comply with the standard. 
N O T E
If you are mounting the base to
a soft material like plasterboard
or if you are using the old
mounting holes, the screws
may not hold. Drill a 3/16-in.
(4.8mm) hole at each screw
location, and insert the plastic
anchors provided. Then mount
the base as described below.
C
A
U
T
I
O
N
Be careful not to drop the body or disturb electronic parts. 
Leave the cover closed while the body is being removed from the base.
TERMINALS
SCREW
ANCHORS
BASE
W3
E
G Y
R
O W2 B
L
R
G
O
Attaching Wires
4. Hold the base against the wall, with the wires coming through wherever
it is convenient for wiring. Route the wires to below the terminal block.
Position the base for best appearance (to hide any marks from an old
thermostat). Attach the base to the wall with the two screws provided.
WARNING: Use Energizer® or 
DURACELL® Alkaline Batteries ONLY 
for all Lux thermostats requiring batteries.