USE AND CARE INSTRUCTION 
 
 
INSTALLATION INSTRUCTION GUIDE  
 
BUILT-IN OVEN TO CABINET UNIT: 
 
The oven may be built-in either in a column or under countertop of a suitable cabinet unit. 
 
Cut-out opening dimensions to be performed on cabinets are indicated in fig. 1. Make sure cabinet unit in which the 
oven is to be fitted is sufficiently sturdy to take the weight of the appliance, approx. 45 kg. 
On the bottom of the unit and/or on the shelf supporting the oven, remember to do the cut-out section at the back, see  
fig. 1, to allow fresh air passage for appliance cooling. 
Ensure that the oven is firmly fixed on provided cut-out. Use screws “A” , fig. 2, to secure oven. 
 
CHARACTERISTICS OF CABINET UNIT:  Cabinet Unit technical requirements as follow;  
- The unit and its components must be able to resist a temperature of 150°C without becoming unglued or warped. 
- The unit must allow free passage of the electrical connections as well as gas tubing in case is needed. 
 
 
OVEN ELECTRICAL CONNECTION. 
 
IMPORTANT. 
- This appliance must be connected to power supply only by a skilled authorised personal. 
- Electrical connection must comply with requested local product electrical standard requirements. 
- It must be powered by a single-phase 230 VAC - 50 Hz electrical connection; 
 
EARTH OR GROUND CONNECTION IS MANDATORY.  
- If electrical wiring is made directly to wall outlet, it is necessary to apply a breaker type of switch suitable to appliance   
  electrical power and standard requirements. 
- IN ANY TIME, GROUND WIRING MUST NOT BE INTERRUPTED BY A SWITCH OR SIMILAR  
  COMPONENT. 
 
THE APPLIANCE MUST ALWAYS BE DISCONNECTED FROM POWER SUPPLY BEFORE 
PERFORMING ANY MAINTENANCE AND SETTINGS. 
 
The appliances could be supplied with an electrical flexible cord without plug. In case of plug application, use a suitable 
plug in accordance to the appliance technical specifications. Remember to properly connect the ground or yellow/green 
wire to the plug’s ground lead 
 
In case of flexible cord replacement or application, read following instruction:  
- Disconnect electrical power supply. 
- Open terminal block cover (fig. 3 and 4). 
- Fix flexible cord leads properly as indicated in figure 4, remember the yellow-green lead is ground. 
- The flexible cord must always be secured by the cord clamp (fig. 4) on terminal block, so may not become loose by  
  being pulled accidentally. Also, make sure flexible cord does not touch hot point of over 75 °C through out the entire  
  cord length.  
- Electrical plug must be suitable to appliance purpose, as mentioned before.  
 
ATTENTION: Use only electrical flexible cord with three-prong assembly, type H05RR-FH 3 x 1.5
 
 
THE MANUFACTURER DECLINES ANY LEGAL AND WARRANTY RESPONSIBILITY FOR NOT 
FOLLOWING INSTALLATION AND WIRING INSTRUCTION IN ACCORDANCE WITH ELECTRICAL 
EUROPEAN STANDARDS AS WELL AS APPLIANCE USER MISUSE.  
 