Sony grand wega 2-694-282-13(1) User Manual

Page of 83
masterpage:3 columns Right
67
O
th
e
r Info
rm
atio
n
F:\Worker\SONY TROY2 ANA EN 12(1)\2694282121\01US08OTH.fm
KF-42/50E200A
2-694-282-12(1)
4
Remove the outside lamp cover. (Choose your model type A or B.)
5
Remove the lamp door.
Turn the knob counterclockwise to OPEN and pull out the cover.
6
Pull out the lamp.
Hook a finger through the loop of the lamp handle and pull the handle 
upwards. Then pull the lamp straight out.
7
Put the new lamp into its place.
Mount the new lamp securely. Failure to do so may cause a fire or the 
screen to go dark.
The lamp is very hot immediately after use. Never touch the 
glass portion of the lamp or the surrounding parts.
After the used lamp has cooled, place it into the empty box 
of the replacement lamp. Never put the used lamp into a 
plastic bag.
If the lamp is not securely reattached, the self-diagnostic 
function may be triggered and the POWER indicator flashes 
three times (see page 11).
B
A
Lamp door
(Continued)