Sony HDW-S280 User Manual

Page of 92
80
Warning Messages
  
Ch
apt
er 10
   
Ma
int
ena
nc
e and
 In
s
pec
tion
10-4  Warning Messages
If the unit detects abnormal status that has been set to be 
detected, the warning mark flashes at the right bottom in 
the display window. Even if the warning mark is flashing, 
you can operate the unit. When you press the MENU 
button together with the SHIFT button, a warning message 
appears in the display window. The warning message is 
stored in the error logger menu.
Warning messages
Setting the warning message to be 
detected
1
Press the MENU button together with the PAGE 
button.
The WARNING screen appears.
2
Press the C EDIT function button.
3
Turn the MULTI CONTROL knob to display an item 
to be detected in the display window.
On the video monitor screen, move * to an item to be 
detected.
4
Press the ON/OFF function button to go out OFF.
5
Press the SAVE function button.
The setting is stored, and the set message will be 
detected.
Canceling detecting warning messages
Select a warning message to be cancelled, and press the 
ON/OFF function button to display OFF.
Message
Description
REFERENCE 
MISSING
No reference signal is input.
LOST LOCK
Capstan servo lock is released 
during playback, recording or editing.
NO VIDEO INPUT 
REC
No video signal is detected during 
recording.
ASYNCHRONOUS 
VIDEO REC
Phase difference of the video input 
signal and reference signal exceeds 
the allowable range during recording.
APR HARD AU 
MUTING
An audio signal is muting because of 
unlocking of PLL in an audio circuit.
HD TG UNLK AU 
MTING
An audio signal is muting because of 
unlocking of PLL of the HD timing 
generator.
SD TG UNLK AU 
MUTING
An audio signal is muting because of 
unlocking of PLL of the SD timing 
generator.
NO RF AU MUTING
An audio signal is muting because 
data on a tape cannot be read.
AUX DATA AU 
MUTING
An audio signal is muting because of 
incorrect system frequency.
VIUC
DF                 INT- PRE    F-RUN     REM:    
M
0
–10
–20
–30
–40
1
CH1 IN :
CH2 IN :
OUT   :
MONI L :
MONI R :
+4
INPUT : SDI
+4
COND
SHIT
 
 
+4
 1
 2
SDI 
59.94i
2
0
–10
–20
–30
–40
3
4
00:00:00:00 
(01):REFERENCE MISSING
C EDIT
ERR LOG
EXIT
WARNING
Warning message