Sony storstation lib-d81 User Manual

Page of 56
30
Chapter 3  Basic Usage
High internal temperature
The ERROR/WARNING LED lights orange and the [0 6] code appears on the 
message display. Suspend operation or lower ambient temperature. When the 
AIT autoloader internal temperature returns to normal levels, the ERROR/
WARNING LED goes out. It is possible for the air filter to become clogged with 
dust or other particles. To prevent this from happening, be sure to clean the air 
filter regularly. For details, see “Maintenance” (page 33).
Specific parts have reached the end of their service life
The ERROR/WARNING LED lights orange and the [0 7] code appears on the 
message display. Contact customer service.
Errors
When an error occurs in the AIT autoloader, the ERROR/WARNING LED 
flashes orange and an error code appears on the message display. For 
information about error codes, see “Error Code List” (page 47) in the 
“Appendix”.
Example: Problem with a cartridge
[C ] and [XX], where “XX” is the error code, appear alternatively on the 
message display.
Example: Problem with the autoloader
[L ] and [XX], where “XX” is the error code, appear alternately on the message 
display.
WARNING
CLEANING
ERROR
WARNING
CLEANING
ERROR