Nokia 3600, 3620 Service Manual

Page of 42
NHM-10
Company Confidential
3 - Service Software
CCS Technical Documentation
Page 3-16
         Copyright  2004 Nokia Corporation
Issue 2 01/2004
Company Confidential
Figure 4: Energy Management Calibration screen
2) Press Calibrate button.
After successfull calibration Calibrated indication is shown.
3) Press Save To Phone to save tuning values into phone memory.
After successful saving Values written to phone is indicated.
4) Verify tuning values saving by pressing Read from Phone.
ZOCUS calibration
Zocus calibration is an addition to the existing Energy Management calibration function 
done with the JBV-1. This new calibration function is available in Phoenix version A8 
2003.17.3.12 and later.
Zocus calibration can be done now in Module Jig MJS-51 or with the Docking Station 
Adapter MJF-31 & Docking Station JBV-1.
When Zocus calibration is needed:
Zocus requires re-calibration only, if the Zocus device (N301, LM3819) itself is replaced, 
any of the components on the sense input (R383, R384 and C386) or if the flash memory 
is corrupted. Zocus does not require re-calibration, if the UEM device is replaced or if any 
of the other energy management calibrations are re-calibrated.