DA-11 Docking Station Adapter and RF Coupler SA-36
The SA-36 is used with DA-11 for RF testing. RF tuning is not allowed by SA-36. It has 
been designed for calibration and soft ware update use. The Docking Station Adapter 
makes signal connections to the phone. 
DA-11 main electric functions include:
adjustable VBATT calibration voltage, current measurement limit voltage "VCHAR", current mea-
surement calibration current "ICHAR"
adjustable ADC calibration voltage via BTEMP and BSI signal
BTEMP and BSI calibration resistor
signals from FBUS to the phone via parallel jig
control via FBUS or USB
Flash OK/FAIL indication
In calibration mode DA-11 is powered by external power supply 11-16V DC. In flashing 
power for the phone can be taken from FPS-8 or external power supply 11-16V DC.
DA-11 main electric functions are:
phone recognizing from BTEMP