LG nk114p User Manual

Page of 1
SPECIFICATIONS for LG HERMETIC COMPRESSOR (Preliminary)
LG
R407C
Standard Dimensions
90
±
5
120
Φ
150
3 - Φ19.1
S
R
C
Φ
118.5
0.15
0
DIS.  I.D   8.06
35
SUC.  I.D  9.7
0.15
0
27
5
24
0
245.9
45
.9
2.3
93
±
3
Φ
50.8 
20
0
±
1.5
7.5
Detail of ⓑ
10
.0
0.5
Detail of ⓐ
15
.9
35
19
.1
N K 1 1 4 P 
1PH, 220/240V 
– 50Hz
Application Range
Compressor Cooling         Natural    
Eva. Temp.   Range         -10℃ ~ 12℃
14℉ ~ 54℉
Condensing    Temp.   
65℃ max.    
149℉ max.
Return Gas    Temp.        35℃ max.     
95℉ max.
Discharge gas Temp.        115℃ max.     
239℉ max.
Motor Wire    Temp.        130℃ max.    
266℉ max. 
Rated Performance
Capacity                   5,850/5,950 Btu/h       1,714/1,744 Watts
Motor Input                557/578 W
Current                    3.0/2.8 A
EER                        10.5/10.3 Btu/W.h       3.08/3.02 W/W
Compressor Data
Design                     Rolling Piston Typed Rotary
Displacement               11.4 cc/rev         
0.69 in
3
/rev
Oil / Oil Charge           FVC 68D 
330 cc 
Weight 
11.4 Kg                 25.1 lb  
Motor Data
Motor Type                 2 Pole Induction (PSC)
Voltage Range              198 V to 264 V
Locked Rotor Amps.         15 Amps.
Electrical Components
Compressor Mounting
Wiring Diagram
Line
Running Capacitor
Compressor
C
S
R
O.L.P
C.S.R mark is embossed on  a  Cover  Terminal
Comp. Tri-plate
Bolt, Stud
Nut, Hexagon
Grommet
Unit  Base
28 m
m
(1
.10 in
ch
)
Washer, Plain
Running Capacitor          25 ㎌
370 VAC
Overload Protector         MRA 12012-12026 (Texas Instruments )
Capacity Test Conditions
Evaporating  Temp.   
7.2℃
45℉
Condensing   Temp.        54.4℃
130℉
Return Gas   Temp.        35.0℃
95℉
Liquid 
Temp.        46.1℃
115℉
Ambient      Temp.        35.0℃
95℉
Specifications are subject to change without notice.
Normal Performance value ±5%.
Air Conditioning Compressor Division