Operating Instructions
For Your Safety, Read Safety Precautions And 
Lighting Instructions Before Operating
T
URN
 O
FF
 U
NIT
:
Flip switch to OFF to turn off burners only.
If the fireplace is to be turned off for the season, or for servicing, turn the gas shut off valve to OFF. If 
the unit is going to be serviced, turn off the electrical power to the unit as well.
NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF, 
for the first two to four hours. This will cure the paint, logs, gasket material, and other products used 
in the manufacturing process. It is advised that a door or window be opened, as the unit will start to 
smoke, which can irritate some people. After the unit has gone through the first burn, turn the unit OFF, 
including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good 
gas fireplace glass cleaner, available at your local Enviro dealer. See “D
OOR
 R
EMOVAL
” and “C
LEANING
 T
HE
 
G
LASS
” sections.
B
LOWER
 S
PEED
:
The blower will come on only when the fireplace is up to temperature (approximately 
20 minutes). Turning the fan control knob will change the speed of the fan. To turn 
the blower off, turn the knob COUNTER-CLOCKWISE until it “clicks” off  (Figure 6). 
It is advisable not to operate the blower below 
1
/
3
 speed as it puts a strain on the 
windings of the blower and running the blower at lower speeds could also cause 
premature fan failure.
N
ORMAL
 S
OUNDS
 D
URING
 O
PERATION
:
Table 2: Normal Sounds.
Component
Sound & Reason
Focus & Fascia
Creaking when heating up or cooling down.
Burner
Light pop or poof when turned off; this is more common with LP units.
Temperature Sensor
Clinking when it senses to turn the blower on or off.
Pilot Flame
Quiet whisper while the pilot flame in on.
Blower / Fan
Air movement that increase and decreases with the speed of the blower. The 
blower is pushing the heat from the fireplace into the room.
Gas Control Valve
Dull click when turning on or off, this is the valve opening and closing.
��
���
��
Figure 6. Fan control.
A
DJUSTING
 V
ENTURI
 A
IR
 S
ETTINGS
:
There is one venturi adjustment.
Use this venturi adjustment lever, shown in Figure 7,  to 
achieve a proper and efficient flame.
Adjust lever until the flame pattern is similar to Figure 
36.  Suggested  pull  out  distances  are  1⁄2”  (13  mm) 
minimum for Natural Gas and 7⁄8” (22 mm) minimum 
for Propane.
Pull out the venturi adjustment to increase primary air at the venturi tube.
Push in the venturi adjustment to decrease primary air at the venturi tube.
Figure 7: Adjusting the venturi air setting.