Enviro DV36 User Manual

Page of 40
3"
(76mm)
12"
(305mm)
6"
(152mm)
14"
(356mm)
Top of unit
3” (76mm) mantle
10" (254mm) mantle
Combustible front face
3
/
4
" (19mm) facing board
Figure 23.  Combustible Mantel Clearances for Fascia or 
Insets.
Initial Installation
QUALIFIED INSTALLERS ONLY
16
A shelf may be installed above the unit. We 
recommend that no heat sensitive items or 
components  be  placed  on  the  shelf  (see 
Figure 22).
M
ANTEL
 C
LEARANCES
:
It is not necessary to install a mantel, but if one is desired it is important to follow the guidelines. 
Note: Louvers have different mantel clearances than when fascia or insets are installed.
Table 3: Mantel clearances.
Louvers Only
Fascia or Insets
Top of unit to horizontal framing
3” (7.6 cm)
3” (7.6 cm)
Top of unit to bottom of 3” (7.6 cm) mantel
12” (30.5 cm)
Top of unit to bottom of 31⁄2” (8.9 cm) mantel
8” (20.3 cm
Top of unit to bottom of 10” (254 mm) mantel
10” (25.4 cm
14” (35.6 cm)
Top of unit to bottom of 3⁄4” (19 mm) facing board
6” (15.2 cm)
6” (15.2 cm)
3"
(76mm)
Top of unit
Combustible
front face
Combustible board
Figure 22.  Combustible Shelf Clearance.
Figure 21.  Raised Fireplace with no Hearth
Even  though  the  DV36  can  be  installed  at  floor 
level  without  a  hearth,  there  are  a  few  options 
with  raised  fireplaces:  raised  with  a  floor  level 
hearth  (Figures  19),  raised  with  a  raised  hearth 
(Figures 20), or raised with no hearth (Figures 21). 
If the fireplace is raised, it cannot be placed within 
37 inches (1.04 m) of the ceiling. When installing 
a raised fireplace, it is imperative that the support 
stand is strong enough to hold the weight of the 
fireplace and venting.