Enviro DV36 User Manual

Page of 40
Initial Installation
QUALIFIED INSTALLERS ONLY
I
NSTALLATION
 O
F
 E
LECTRICAL
 W
IRING
 F
OR
 T
HE
 O
PTIONAL
 F
AN
 K
IT
:
Figure 39.  Wiring Diagram For Gas Valve.
COOL / HEAT
PROGRAM
DOWN
UP
70 ° F
70 ° F
ON
OF
F
Optional
Remote
Control
ON/OFF/Remote
Thermostat Switch
Purple
Thermocouple
Blue
Thermopile
Grey
Inlet
Pressure
Tap
Gas Control
Valve
Manifold
Pressure Tap
Pilot Adjustment
Screw
Optional
Wall Switch
Optional
Thermostat
Wire Size
Max. Length
14 gauge
100 ft  (30.48 m)
16 gauge
60 ft   (18.29 m)
18 gauge
40 ft   (12.00 m)
20 gauge
25 ft   (7.62 m)
22 gauge
18 ft   (5.49 m)
Table 9.  Recommended Thermostat 
Wire Size.
27
Figure 38. Install Electrical Outlet Into DV36.
The electric box/outlet must be hard wired to 
the  bottom  left  (or  right  if  the  gas  line  is  to 
come in on the left) of the unit if you plan to 
install the Optional Fan Kit in the future.
Refer  to  local  electrical  bylaw  for  proper 
installation.  In  the  absence  of  local  codes, 
with the current CSA C22.1 Canadian Electrical 
Code  Part  1,  Safety  Standards  For  Electrical 
Installations, or The Current National Electrical 
Code ANSI / NFPA 70 in the US.
E
LECTRICAL
 S
YSTEM
 F
OR
 T
HERMOSTAT
:
CAUTION:  Label  all  wires  prior  to  disconnection  when  servicing  controls.  Wiring  errors  can  cause 
improper and dangerous operation. Verify proper operation after servicing.