2. Start the pilot by pressing the gas control knob and turning it to PILOT.  
While holding the gas control knob in, press the piezo ignitor several 
times until the pilot light starts. Hold the gas control knob in for 30 
seconds.  Check  that  the  pilot  has  fully  engulfed  the  thermocouple 
assembly (see Figure 3).
3. Start the main burner by turning the gas control knob to ON and then 
turn the rocker switch to ON. Check that all burner ports have flame.
4. Leak test all gas joints again.
A
IR
 S
HUTTER
:
The air shutter adjustment lever is centered above the controls (see Figure 4).
The air shutter allows the amount of air coming into the fireplace to be adjusted in order to accommodate 
different climates and venting arrangements. Start the pilot and then the burner. Make sure the pilot 
flame is burning normally and none of the burner ports are plugged. Let the fireplace burn for roughly 
fifteen minutes and then examine the flames, compare the flames to Figure 40.
The ideal flame will be blue at the base and light orange above. The flames should be of medium height. 
If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly 
���� ��� � ����
���� ��� � �����
��� �������
blue,  the  fireplace  is  getting  too  much 
air. Therefore, the air shutter should be 
closed (push in) slightly until the correct 
flames  are  achieved.    Flames  that  are 
very orange, with tall, dark, stringy tips, 
are  not  getting  enough  air.  Open  (pull 
out)  the  venturi  until  the  flames  clean 
up. If the venturi is opened, or closed all 
the way, and the correct flames cannot 
be attained, turn off the gas and contact 
the dealer.
Warning: Incorrect venturi adjustment 
may lead to improper combustion, which 
is a safety hazard. Contact the dealer if 
there  is  any  concern  about  the  venturi 
adjustment.
Figure 4.  Air shutter adjustment lever.
����������
������������
Figure 3.  Pilot Flame
7
Operating Instructions
P
ILOT
 L
IGHT
:
1. Turn off the gas to the fireplace.  If not recently done, remove the glass and let the unit air out 
for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints 
with soapy water. NEVER USE OPEN FLAME FOR LEAK TESTING. 
R
EMOTE
 
CONTROLS
:
This fireplace can use an optional remote control or an optional cordless wall thermostat.  If either of 
these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the 
control panel) in the remote/thermostat position.  Consult the instructions included with the remote/wall 
thermostat for operation guidelines.