F
UEL
 C
ONVERSION
:
TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY
Please read and understand these instructions before installing. 
Warning:  This conversion kit shall be installed by a qualified service agency in accordance 
with the manufacturer’s instructions and all applicable codes and requirements of the 
authority  having  jurisdiction.  If  the  information  in  these  instructions  is  not  followed 
exactly, a fire, explosion or production of carbon monoxide may result causing property 
damage, personal injury or loss of life. The qualified service agency is responsible for 
the  proper  installation  of  this  kit.  The  installation  is  not  proper  or  complete  until  the 
operation  of  the  converted  appliance  is  checked  as  specified  in  the  manufacturer’s 
instructions supplied with the kit.
Figure 14: Removing the orifice.
Kit Parts List:
 
Orifice (NG - PO512-42 DMS or LP - PO512-54 DMS)
Installation instruction sheet 
Carefully inspect all parts supplied with this conversion kit. If 
any parts have been damaged or are missing, contact your 
dealer, distributor or courier company to have them replaced 
before starting this installation.
Conversion Kit Installation:
1. Turn control knob on the gas valve to the “OFF” position 
and shut the gas supply off at the shut-off valve upstream 
of the unit.  CAUTION: The gas supply must be shut off 
prior  to  disconnecting  the  electrical  power  and  before 
proceeding with the conversion. Allow the valve and unit 
to cool down to room temperature.
2. Remove the glass door as shown in the M
AINTENANCE
 
AND
 
S
ERVICE
 - G
LASS
 D
OOR
 R
EMOVAL
.
3. Carefully remove the log set.
4. Slide the burner back just far enough so the front edge of 
the burner does not catch on the front lip of the firebox. 
Lift the front of the burner up and out of the firebox. See 
M
AINTENANCE
 
AND
 S
ERVICE
 - B
URNER
 R
EMOVAL
 & I
NSTALLATION
.
5. Convert the burner orifice:
a)  Remove  the  main  burner  orifice  with  a  3⁄8”  socket  
(refer to Figure 14).
b)  Install the alternate orifice from the kit.
6. Convert the pilot injector:
a)  Loosen the pilot stem a half turn using a 
7
/
16
” wrench 
(refer to Figure 15).
b)  Slide the tab to the other side of the pilot stem (refer 
to Figures 16 & 17).
c)  Tighten the pilot stem. 
Figure 15: Turning Pilot Stem.
Figure 16: NG & LP Gas Positions on Pilot.