Enviro cara dr 50-1628 User Manual

Page of 37
Initial Installation
QUALIFIED INSTALLERS ONLY
P
LANNING
 Y
OUR
 I
NSTALLATION
:
The Cara DR is only for horizontal rear vent installations.  The maximum horizontal is 2’ (61 cm) and the 
slope on the vent must be 11⁄4” per foot (3.2 cm per 30 cm).  No vent restrictor is required and no elbows 
are allowed. When planning your installation, it will be necessary to select the proper length of vent pipe 
for your particular requirements. It is important to note when passing through a wall, the maximum 
allowable wall thickness is 10 inches (25.4 cm); 11⁄2 inches (3.8 cm) clearance to combustibles must be 
maintained.  To connect the venting system to the appliance flue outlet, a twist-lock adapter is built into 
the appliance at the factory. 
Note:  If necessary to get above grade the Cara DR can be installed using a 14” or 36” snorkel.
A
PPROVED
 V
ENT
 P
ARTS
:
Table 5: Approved Vent Manufacturers.
Manufacturer
Trade Name
Nominal Sizes
American Metal Products
AmeriVent Direct
4” - 6 5/8”
Security Chimneys International LTD
Secure Vent
4” - 6 5/8”
Selkirk Metalbestos
Direct-Temp
4” - 6 5/8”
Simpson Dura-Vent
Direct Vent GS
4” - 6 5/8”
Table 6: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS).
Direct Vent GS
Direct-Temp 
Secure Vent
Ameri Vent Direct Description
908
4DT-6
SV4L6
6” pipe length
4D7
7” pipe length
907
4DT-9
9” pipe length
906
4DT-12
SV4L12
4D12
12” pipe length
904
4DT-24
SV4L24
4D2
24” pipe length
942
4DT-WT
SV4RSN
4DWT
Wall thimble
970
4DT-HKA
SV0SHK
4DHTK1
Horizontal termination kit (SD: Basic Kit, 
SEL: Kit A, SC: Standard Kit)
984
4DT-HC
SV4CHC
4DHC
Horizontal square termination
The  Cara  DR  fireplace  has  been  tested  and  certified  for  use  with  AMERICAN  METAL  PRODUCTS 
“AMERIVENT DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES.  SECURITY CHIMNEY’S 
“SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for 
horizontal venting.  When using Simpson Duravent, it is recommended that, before installation, a bead 
of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner 
joint.  When planning an installation, it will be necessary to select the proper length of vent pipe for the 
particular requirements.  
WARNING: Do not mix parts from different vent manufacturers’ systems. EXCEPTION TO WARNING:  
This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction 
with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems.  Use of these systems with the 
Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the 
appliance.
15