Installation
Pre-Installation Inspection
Upon delivery, visually inspect crate carton and parts 
for any visible shipping damage. If the crate, carton, or 
cover is damaged or signs of possible damage are 
evident, have the carrier note the condition on the 
shipping papers before the shipping receipt is signed, 
or advise the carrier of the condition as soon as it is 
discovered.
Remove the crate and protective cover as soon as 
possible and check the items listed on the packing list. 
Advise the carrier of any damaged or missing articles 
as soon as possible. A written claim should be filed 
with the carrier immediately if articles are damaged or 
missing.
IMPORTANT: Warranty is void unless tumbler is 
installed according to instructions in this manual. 
Installation should comply with minimum 
specifications and requirements detailed herein, 
and with applicable local gas fitting regulations, 
municipal building codes, water supply regulations, 
electrical wiring regulations, and any other 
relevant statutory regulations. Due to varied 
requirements, applicable local codes should be 
thoroughly understood and all pre-installation 
work arranged for accordingly.
Location Requirements
The tumbler must be installed on a level floor capable 
of supporting weight of tumbler fully loaded. Floor 
covering materials such as carpeting or tile should be 
removed.
To assure compliance, consult local building code 
requirements. The tumbler must not be installed or 
stored in an area where it will be exposed to water 
and/or weather.
IMPORTANT: DO NOT block the airflow at the 
rear of the tumbler with laundry or other articles. 
Doing so would prevent adequate air supply to the 
combustion chamber of the tumbler.
A typical tumbler enclosure is shown in Figure 1. Note 
the minimum and maximum dimensions. Local codes 
and ordinances must be complied with.
IMPORTANT: Install tumblers with sufficient 
clearance for servicing and operation. Refer to 
Figure 1
.
IMPORTANT: Keep tumbler area clear and free 
from combustible materials, gasoline and other 
flammable vapors and liquids.
Material Required (Obtain Locally)
All Models
One disconnect switch or circuit breaker.
Gas Models
One gas shut-off valve for gas service 
line to each tumbler.
Steam 
Models
One steam shut-off valve for steam 
service line to be connected upstream of 
solenoid steam valve.
Steam shut-off valve for each condensate 
return line.
Flexible steam hoses with a 125 psig 
(pounds per square inch gauge) 
(8.78 kg/sq. cm) working pressure for 
connecting steam coils. Refer to 
Figure 15 for sizing and connection 
configurations.
Steam trap for steam coil outlet to 
condensate return line.
Optional – Vacuum breaker for 
condensate return line.
To reduce the risk of serious injury, install 
lockable door(s) to prevent public access to 
rear of tumblers.
W055
WARNING